From leach to final cathode, a modern solvent extraction–electrowinning (SX–EW) plant runs on control charts, on‑line probes and tight sampling. The result is Grade‑A copper at ≥99.95% purity and a current efficiency that is measurably higher.
The market now demands in‑country refining. Indonesia’s Permen ESDM No. 7/2023 raises the stakes (peraturan.bpk.go.id). Therefore SX–EW operators fit their plants with sensors and lab checks to guarantee ≥99.95% Cu (ASTM B115, standards.iteh.ai). The quality plan starts upstream. There we watch pH, [Cu], [Fe], H₂SO₄, trace impurities, temperature, phase ratios and current density.
On‑line analyzers (pH probes, flow meters, in‑line copper monitors) and automated controllers for acid dosing keep setpoints tight. In this context it is standard practice to tie dosing to a dosing pump with interlocks. Laboratory assays (AAS/ICP‑OES and titration) validate those numbers, and all of it feeds into control charts. One study put a 5.4% rise in current efficiency down to this kind of statistical process‑control discipline. That rise gave ~74 t of 99.999%‑pure cathode over 1.5 months (scielo.org.za).
Pregnant leach solution sampling
The pregnant leach solution (PLS) is the acidic liquor that comes out of the ore heaps. We sample it at least hourly. A typical copper‑oxide heap leach can run around ~2.0 g/L Cu and 2.7 g/L Fe in solution (mdpi.com). The goal is steady leach efficiency, for example 90–95% Cu dissolution, with little dissolved Fe/Al. Operators titrate for acid, run ICP/AAS for Cu, Fe, Al, Mn, As and others, and log pH and redox continuously. Keeping pH ~1.5–2.0 matters because a pH shift hits both acid consumption and Cu extraction efficiency.
Mass balance is non‑negotiable. Flow × concentration must add up. Any copper loss that cannot be explained starts root‑cause work, for example scaling or a mechanical fault. For solids control, turbidity meters or particle counters make sure the CIL plant (if present) is not overloaded with fines. This prevents organic carry‑over. Where a clarifier is installed upstream, it reinforces that solids barrier ahead of SX.
Targets and alarms are explicit: >90% Cu recovery per pass. Acid consumption is around 200–400 kg H₂SO₄ per metric tonne of Cu, with PLS pH ~2.0. Any deviation in Cu or Fe by >5% from the daily average prompts corrective action. We watch the trends. A rising Fe or a falling Cu usually comes before a plant upset.
Solvent extraction stage control
Most circuits run two extraction stages, one to two scrub stages, and two strip stages. In extraction, mixer‑settler pH sits ~1.4–1.6 (for oxime‑ or phosphoric‑based extractants) to load copper and reject iron. In one test at pH 1.6, the Cu distribution ratio exceeded 70 while Fe’s D≈0.12, giving a Cu/Fe selectivity (β) of ~600 (mdpi.com). Raffinate Cu is driven below <0.5 g/L, and usually below <0.1 g/L in steady state.
Operators assay organic phase copper by strip-titration or spectrophotometry, and raffinate Cu by on-line AAS/XRF. O/A flow ratios and contact times are kept constant. Flow meters are checked weekly. Mixer temperatures sit in the 20–30°C band. Too high accelerates extractant degradation. Too low slows kinetics.
Scrubbing and stripping setpoints
Scrubbing uses mild acid (or dilute PLS) at ~0.5–1.0 M H₂SO₄ to rinse Fe/Al/Mn from the loaded organic before stripping. Washed‑loaded organic should show negligible Fe, usually <0.02 g/L. If it does not, the plant adds scrub capacity or imposes a bleed.
Stripping regenerates lean organic and builds copper-rich electrolyte. Plants maintain strip acid ~150–210 g/L H₂SO₄, with 200 g/L preferred (data.epo.org). Strip liquor Cu lands ~45–60 g/L (researchgate.net, pdfcoffee.com). One pilot reported 44.8 g/L Cu with just 1.4 g/L Fe in strip (researchgate.net).
Because the electrolytic bath originates here, soluble contaminants (Pb, As, Zn) are tracked at strip. Analyses reference ASTM B115 limits, which allow Se, Te <2 ppm (standards.iteh.ai). Online interlocks shut acid addition pumps if an acid meter fails. This prevents runaway pH.
Organic phase health checks
Solvent quality, extractant plus diluent, is watched continuously. Water pickup is measured by Karl Fischer titration or on‑line density meters. Phase entrainment must be <1–2%. If it is exceeded, operators adjust settler residence time or add a decanter. Free (unused) extractant is tracked via titration. A drop indicates degradation or loss, with a target of >95% active reagent.
Periodic checks also cover biodegradability and solvent drag loss. The organic should stay clear, with no suspended solids. Specific gravity should stay within ±2% of the fresh solvent.
Solvent extraction equilibrium shows Cu loading vs pH. Running at pH ~1.6 gives ~95–99% Cu extraction with little Fe uptake (mdpi.com).
Electrowinning electrolyte control
The tankhouse runs on composition discipline. The standard is about 40–60 g/L Cu and about 150–210 g/L H₂SO₄ (usually about 180 g/L). One industry example is 40 g/L Cu at 180 g/L acid (data.epo.org, pdfcoffee.com). Temperature holds at about 40–50°C to lower resistivity (about 1.4 Ω·cm, pdfcoffee.com). Chloride sits at about 30–80 mg/L for deposit brightness. Too much pits, too little dulls (data.epo.org).
Continuous recirculation keeps the bath homogeneous. On‑line sensors watch Cu and specific gravity. Significant drift, say Cu <35 g/L or acid <150 g/L, sets off an alarm because low acid pushes up cell voltage and promotes impurities. Water quality (deionized) is QC‑checked weekly to prevent scaling or sulfate buildup. Many plants generate that makeup via a demineralizer or, for continuous ultrapure service, EDI.
Electrical parameters and monitoring
Current density usually runs 200–300 A/m² (20–30 A/dm²). Many plants use periodic polarity reversal to minimize anode skin. One documented sequence used 15–25 A/ft² forward pulses (≈160–270 A/m²) with short reverse pulses (30–40 A/ft²). It achieved 90%+ cycle efficiency (freepatentsonline.com). PLCs record cell voltages and target ~2.0–2.3 V under load. A fast rise points to short‑circuiting or anode passivation.
Bath circulation rate and anode–cathode gaps are fixed. A conductivity sensor may be used to detect large particulate in electrolyte (which would increase resistance). Sample filtration before analysis usually uses a cartridge filter to remove fines without altering dissolved metals.
Cathode product verification
Finished cathodes must meet purity grades. Namibia’s SX–EW plant has reported Grade‑A copper at 99.999% Cu (scielo.org.za). Final QA includes weighing and assaying sample cathodes. Monthly, cathode samples go out for trace‑metal analysis by ICP‑MS/AES (Se, Te, Pb, Ni, etc.). ASTM B115 specifies Se/Tellurium <2–10 ppm (standards.iteh.ai). Resistivity checks (for conductivity) and morphology (SEM) reveal dendrites or occlusions. Any “off‑spec” cathode (for example >0.05% impurity) triggers a review of upstream scrubbing/stripping.
Performance metrics close the loop. Current efficiency should be above 90%, and a tuned process reported 90–94%. Energy use is about 2–3 kWh/kg Cu (freepatentsonline.com). Removing voltage "hotspots" in one tankhouse raised efficiency by +5.4% (scielo.org.za). That is tens of tonnes of additional cathode.
Sampling plan and laboratory methods
A formal sampling plan is the base of the whole program. Automated and manual samplers are installed on PLS feed, SX raffinate, loaded/lean organic, strip liquor, and EW electrolytes. The important streams get grab samples every hour. Other streams are sampled once per shift. Samples are filtered and acidified on collection if needed (for example, add HNO₃). Duplicate and blank samples check consistency. Results go into a LIMS and are plotted on control charts.
Lab work is standardized. Metals (Cu, Fe, and others) are measured by AAS or ICP-OES following standard methods (for example, ASTM E203 for Cu). Acid content (sulfate) is measured by titration with NaOH (ASTM E200). pH and conductivity are measured by calibrated probes, with daily calibrations. Organic-phase copper is measured by stripping a known volume with acid and assaying that strip, or by phase separation and UV-vis/colorimetry. Water content in organic is measured by Coulometric Karl Fischer, with a target below 1%.
Quality checks anchor decisions. If a result exceeds specification, for example Cu concentration off by more than 3σ of normal, the sample is re-tested. If confirmed, the process is adjusted immediately: change O/A flow, tweak SX pH, or divert electrolysis cells. Weekly and monthly audits review data, batch yields, and reagent usage records. Major deviations, such as a run of falling current efficiency, trigger root-cause analysis. This ranges from cleaning electrode racks to pulling forward preventative maintenance on pumps and agitators. Where fines management is part of the plan, an upstream clarifier complements the turbidity and particle-count controls already in place.
Why the discipline pays
Across leaching, SX and EW, the QC scheme combines continuous monitoring (pH, flows, [Cu]) with periodic laboratory verification. It enforces spec limits at every stage. Therefore the cathodes stay consistently high grade and meet ≥99.95% Cu (ASTM B115, standards.iteh.ai). This also supports yield and cost efficiency. The reported results show a 5.4% efficiency gain and ~74 t of 99.999% cathode in 1.5 months (scielo.org.za). Some plants need temporary solids or water polishing during upsets. For these, containerized options and filtration hardware are common parts of the tool kit. They complement the core controls and do not change the setpoints that keep copper on spec.