Inside the packaging hall’s dirtiest secret: a pretreatment train that strips 70–85% of the load before it hits the plant

beta-pramesti-asiaindustry-food-and-beverageprocess-packaging

Inside the packaging hall’s dirtiest secret: a pretreatment train that strips 70–85% of the load before it hits the plant

A dedicated screening–equalization–pH control–coag/floc system can remove ≥80% of suspended solids and up to 70–80% of organic load from Food & Beverage packaging wastewater before it reaches the main WWTP. Bench-scale data, dosing ranges and real-world percentages point to a measurable cut in surcharges and O&M.

Industry: Food_and_Beverage | Process: Packaging

Packaging hall wastewater has peaks, is messy and carries scraps. It holds labels, cardboard, plastics and adhesives, plus pulsed discharges from line washdowns and bottle rinses. A staged pretreatment train built around screening, equalization, pH control and coagulation–flocculation (coag/floc) is the difference between downstream chaos and steady, predictable treatment.

The technical upside is not subtle. With properly sized screens and flocculation, more than 80% of total suspended solids (TSS, fine particulate content) can be removed. Organic load (measured as COD, chemical oxygen demand, and BOD/BOD5, biochemical oxygen demand over five days) usually drops 60–80% under good conditions (MDPI). In one study, 0.4 g/L (400 mg/L) ferric chloride cut TSS from about 1000 to about 150 mg/L and COD by 85% (MDPI).

Industrial guidance also points to a cost angle. High suspended solids “increase BOD” and can lead to sewer surcharges. Primary steps like sedimentation or wedge‑wire screening are usually used to reduce suspended organic solids loading (Wikipedia).

Screening train and solids capture

The first barrier is screening. Coarse bar or drum screens at roughly 10–20 mm pull out bulky debris (cardboard, plastic, errant bottles) before it can clog pumps or foul mixers. Finer screening down to 1–3 mm catches small particles that still carry a large share of particulate BOD and COD. In practice, wedge‑wire and sedimentation steps are used at this stage because suspended solids “increase BOD” and are usually used to reduce suspended organic solids loading (Wikipedia).

Facilities usually put coarse, hand‑raked barriers like a manual screen at the headworks. They then follow with a continuous unit such as an automatic screen to keep capture up without labor‑intensive cleaning. As a package, primary solids removal systems like physical separation trains cut TSS input by a large margin and protect downstream equipment.

Equalization basin and flow buffering

Packaging wastewater is notoriously intermittent. Batch line cleanings and bottle rinses spike both flow and concentration. An equalization tank with a mixer evens out both. Designing for enough volume, usually several hours’ average flow, can more than halve the peak‑to‑trough ratio of flow and BOD/COD. That gives a near‑constant feed that “can quite improve the performance” of downstream treatment and even allow smaller units, according to engineering practice summarized in the paper.

Equalization also becomes the pre‑mixing zone for chemicals. It buffers pH swings from alkaline detergents or acidic rinses before any coagulant is added. Supporting hardware such as mixers, instruments and valves is usually treated as water treatment ancillaries in design and procurement.

pH control ahead of coagulation

Coagulants like alum (aluminum sulfate) and ferric chloride work best near neutral pH. Therefore a pH adjustment system sits at or just after equalization. Continuous monitoring aims for about pH 6.5–7.5 ahead of coagulation. This matches both coagulant efficiency (MDPI) and typical discharge bands (usually pH 6–9). Alkalis (lime or caustic) or acids are dosed as needed.

Accuracy matters here. Therefore plants specify an accurate chemical dosing pump for pH control. The pump is synchronized with equalization tank recirculation, so corrections are distributed quickly and uniformly.

Coagulation–flocculation performance benchmarks

Once screened and equalized, the wastewater is ready for coagulation–flocculation. This is rapid mixing with metal salts, then gentle floc formation and solid–liquid separation. Typical coagulants include alum, ferric chloride, and polyaluminum chloride (PAC). The paper’s jar‑test data point to effective doses in the few‑hundreds of mg/L range. 400–700 mg/L is cited as effective overall. A preliminary design basis of about 0.3–0.6 g/L of alum or PAC is recommended before jar tests refine it.

Specific results: dosing 0.4 g/L (400 mg/L) Al₂(SO₄)₃ at pH 6.5 removed about 74.5% of COD and about 74.5% of TSS. 0.4 g/L FeCl₃ at pH 5.5 removed about 84.5% of COD and about 85.5% of TSS (MDPI). In a fruit‑juice stream with COD ≈ 21,000 mg/L, 0.4 g/L alum achieved 74.5% COD removal and 42.8% turbidity removal. 0.4 g/L ferric chloride achieved 84.5% COD and 54.1% turbidity removal (MDPI).

Those numbers mean an expected 70–85% reduction in organic load (BOD/COD) for high‑strength packaging waste with a lot of particulate, such as sugary rinses. TSS drops by about the same amount. Where the organics are mostly soluble, the result is smaller. A brewery study found that 675 mg/L PAC at pH ≈ 7 cut COD by only about 30% in real effluent (MDPI). This shows where coagulation works: it removes colloidal and particulate BOD. Soluble BOD mostly passes through.

In practice, plants dose a primary coagulant, usually one of the coagulant chemistries such as alum, ferric salts or PAC (for wastewater service, see PAC for industrial wastewater). They then add 1–5 mg/L of a polymeric aid to build larger flocs that settle faster (flocculant polymers). Jar tests (bench‑scale beaker trials) set the type and the dose.

Clarification, flotation, and sludge handling

After flocculation, separation is usually by settling or flotation. A conventional clarifier handles the settled floc stream. Dissolved air flotation (DAF) is favored for lighter flocs that carry grease, and compact DAF units are available as DAF systems. The paper notes that TSS removal is usually ≥80% (the main WWTP then handles the residual TSS and BOD). It also notes that organic load usually drops by 60–80% under good conditions (MDPI). However, very soluble organics may see smaller reductions (MDPI).

Two examples show the scale of the change. If influent TSS is 200 mg/L, 85% removal leaves roughly 30 mg/L. That helps a lot toward final limits like <50 mg/L TSS. Also, one ferric test case cut TSS from roughly 1000 to roughly 150 mg/L and reduced COD by 85% at 0.4 g/L (MDPI).

Chemical treatment raises sludge output, on the order of 0.5–1 kg of dry sludge per kg of coagulant. Therefore the design includes sludge collection and handling (thickening and dewatering). The paper cites collected sludge solids of about 2–5% before dewatering, and disposal has to be planned (for example, landfill of solids). Less organic load to the biological plant also means less sludge made downstream in the biology.

Load reduction to the main WWTP

Beyond TSS, pretreatment gives the biological plant a more stable, cleaner feed. Jar tests suggest BOD5 (five‑day biochemical oxygen demand) reductions of about 70–80%. As a simple sizing context, a packaging flow of 50 m³/day at 300 mg/L BOD5 corresponds to about 15 kg/day of BOD5. After pretreatment, the paper estimates about 3–5 kg/day. That cut usually means lower sewer charges and reduced O&M.

The summary in the paper ties these gains to compliance in Indonesia. It notes that the combined train helps meet Indonesian effluent limits and supports outcomes like <50 mg/L TSS and <20 mg/L BOD in final discharge (MDPI).

Design assumptions and monitoring

The proposed train is coarse plus fine screening, equalization/pH control, and coagulation–flocculation. Bench data and standard practice back it. Typical coagulant doses are a few hundred mg/L. Start around 0.3–0.6 g/L for alum or PAC, then refine with jar tests. Polymer doses of 1–5 mg/L usually follow the coagulant. pH is continuously monitored and held near 6.5–7.5 ahead of coagulation. This matches coagulant efficiency and the typical discharge band of pH 6–9 (MDPI).

The paper recommends regular performance checks on TSS, BOD and pH. It also recommends jar tests to fix the coagulant type and dose. Instrumentation, mixers and solids‑handling gear are specified as wastewater ancillaries to keep the system dialed in.

Key performance summary

With properly sized screens and flocculation, more than 80% of TSS can be removed. Up to 70–80% of organic load (COD/BOD) can be abated (MDPI, MDPI). The main WWTP then handles the residual TSS and BOD. For example, one study reported that 0.4 g/L ferric chloride cut TSS from about 1000 to about 150 mg/L and COD by 85% (MDPI).