Fouling in alkylation heat exchangers cannot be avoided. However, a combined program of tight water chemistry, targeted antifoulants and two-stage chemical cleans can extend run length and recover serious money.

Industry: Refinery | Process: Alkylation

Fouling is a slow choke. In alkylation units, polymerized olefins, carried-over catalyst and inorganic scale build on tube walls. They drive up temperatures and pressures and cut heat transfer and flow. One industry source is blunt: fouling "leads to less efficient plant operations due to reduced heat-transfer capacity and lower fluid flow…[and] increased corrosion…resulting from metal oxide deposition and overheating" (chemicalprocessing.com).

Even high velocities only buy time. Engineers "size the exchanger tubes so speed through the tubes is as high as possible to increase the duration before fouling starts…however, fouling is an inescapable fact when heat exchangers are used" (epcmholdings.com).

Alkylation deposit mechanisms and hotspots

Alkylation-specific foulants include organic polymeric deposits, such as HF red oil resins (a resinous by-product formed via aldol condensation of hydrocarbons), and inorganic salts (carbonates or sulfates after sulfuric acid service, fluorides from HF). A vendor case shows where it bites hardest: "heat exchangers, reboilers, and acid separators have the heaviest fouling… Inorganic scaling can foul exchanger bundles so much that they are impossible to pull" (fqechemicals.com).

Mixed deposits (“grease, coke, asphaltenes and scales”) lower the overall heat-transfer coefficients (U-values). A model of a refinery network found that once the overall U falls about 40% from clean, energy efficiency drops a lot. Cleaning at a 40% U-drop works better than waiting longer (journal.ugm.ac.id).

Fouling layers insulate the tube surfaces. This lowers the effective heat-transfer coefficient and raises the pressure drop (chemicalprocessing.com, epcmholdings.com).

Process control and feed pretreatment

Operators start with basic discipline. Feed streams are pre-treated to remove heavy polymers or particulates (for example DRI filters on alkylation feed). Stable conditions also curb polymer formation: temperature, acid strength and a moderate olefin concentration. Continuous monitoring of pressure drop and inlet/outlet temperatures gives early warning of deposit buildup.

Cooling‑water chemistry and filtration control

On the water side, filtration and chemical treatment hold back particulate and feedwater fouling. Cooling-tower scale inhibitors (polyphosphates, polymers, biodispersants) are dosed routinely to prevent calcium and carbonate scale (watertreatment.qualichem.com). One expert notes flatly that keeping the cooling water “clean… is the best way to avoid particulate fouling” (swep.net).

Programs usually combine scale inhibitors with corrosion inhibitors and biocides to keep rust and biofilms from settling. In practice, many sites set cooling-circuit limits (for example less than 200 ppm Ca) and schedule blowdown to avoid buildup. Where dispersancy is needed, dispersant chemicals help keep particulates in suspension.

Chemical antifoulant injection in service

Beyond water chemistry, some units inject chemical antifoulants into process loops. These include dispersants, which keep foulants soluble, and polymerization inhibitors. This is less common in alkylation than in crude preheat. However, some units use small-dosed antioxidants or inhibitors (for example nitroxides or hindered phenols) to slow polymer formation in olefin feeds.

Heavy hydrocarbon fouling is another target. Refinery operators have trialed nano‑scale surfactant‑dispersants. One magnesium‑sulfonated nano‑additive “appears to be effective on several types of fouling” in upgraders and refineries (digitalrefining.com). In continuous pilot tests that mimic refinery conditions, this additive reduced solid deposits by over 70%. One trial dropped new deposits from ~23 g (no additive) to ~6 g under injection, and the exchanger pressure drop stayed low (researchgate.net).

Real units show similarly striking gains. A crude preheat case achieved a 1.2× increase in overall U using an asphaltene dispersant, and recovered about $60,000/day of throughput (fqechemicals.com). Capacity rose by 15,000 barrels/day with zero downtime for cleaning (fqechemicals.com). Reviews also highlight nanoparticle‑boosted dispersants as a notable trend in fouling control (digitalrefining.com, researchgate.net).

Shutdown chemical cleaning procedure

Chemical cleaning during a scheduled turnaround is still the fastest way to restore performance. A standard two-stage sequence (alkaline then acid) is well established (epcmholdings.com):

  • Isolate and drain. Disconnect the tube-side and shell-side inlets and outlets, pressure-test, and install blinds. Once deposits are removed and the seats are clear, valve leakage is common. Therefore the blinds must seal tightly (chemicalprocessing.com). Flush the residual process fluids (HF, isobutane, caustic). In HF units, drain the acid inventory to the regenerator or neutralize it with caustic before access.
  • Alkaline solvent wash. Circulate a hot alkaline detergent (dilute sodium hydroxide with surfactants and a corrosion inhibitor) to dissolve oils, tars, and soluble organics (epcmholdings.com). For stubborn paraffin/asphaltene fouling, sites use custom "decon" blends or high-flash solvents. One vendor recommends an alkaline degreaser pass before descaling (fqechemicals.com). Typical circulation is 50–60 °C at enough pressure to sweep all tubes, monitored by effluent clarity. Where appropriate, an alkaline degreaser is used. Some programs also add a solvent-based step.
  • Acid descale. After the organics are stripped, apply an acid chosen for the scale. Use hydrochloric, nitric or sulfamic acid for calcium and magnesium carbonates or sulfates, usually with chelants such as EDTA or citric acid (epcmholdings.com). Alkylation needs its own choice: for scaling from hydrofluoric acid, hydrochloric acid “will need to be added with the chemistry” to address fluoride scales such as CaF₂ or AlF₃ (fqechemicals.com). In H₂SO₄ units, hot HCl or proprietary chelants may be used against magnesium sulfate scales. Citric or formic acid cycles are common for iron oxides, but strong HCl attacks carbonates. Add corrosion‑inhibiting packages (for example nitrites or azoles) to protect the steel. Circulate, usually at ~40–60 °C, for several hours. Track pH and acid consumption until the effluent runs free of solids.
  • Rinse, neutralize, passivate. Flush with fresh water, then circulate a neutralizer and passivation chemical. For carbon steel, use dilute sodium carbonate (soda ash) to neutralize residual acid and form a protective oxide (epcmholdings.com). Drain, dry, and return to service.

The two‑stage approach “removes the organic part of residues such as grease and oil” and then “disintegrate[s] scaling and soften[s] residues”. However, severe cases may still need mechanical brushing (epcmholdings.com). Modern formulations can shorten outages (epcmholdings.com). Solvent‑based systems have removed nearly all deposits in the field. In one case the U‑values rebounded by up to 120% after cleaning (fqechemicals.com).

Safety and compliance are central. Neutralize HF or caustic residues before discharge. In Indonesian refineries, spent cleaning fluids are classified as hazardous (Limbah B3). On-site waste systems must treat them fully (neutralized, filtered, etc.) per environmental regulations.

Scheduling thresholds and economic outcomes

Quantified schedules pay off. Huda et al. found that a planned cleaning schedule (125°C) carried out when U had dropped 40% used much less fuel and energy than waiting until 90% decay. The 40% decline point balances energy recovery against cleaning cost (journal.ugm.ac.id, journal.ugm.ac.id). In day‑to‑day practice, many units clean exchangers whenever overall ΔT increases 20–30% or pressure drop doubles, to avoid steeper losses.

Case studies show large upside. The FQE treatment cited earlier restored duty and “recovered $60,000 in lost production per day” (fqechemicals.com). Remesat’s pilots showed that continuous nano-additive injection can almost eliminate fouling. Collected deposits fell to ~1 g (vs grams of coke with no treatment), with pressure drop near baseline (researchgate.net). Even partial treatment at 300 ppm dosing cut deposits from ~23 g to ~6 g, a ~75% reduction (researchgate.net).

Across the literature and field, the pattern is the same. Preventive additives slow the fouling rate (digitalrefining.com, researchgate.net). A well‑planned chemical clean fully restores exchanger performance. A combined program is important. It means water‑treat and antifoulant injection on‑line, plus periodic turnaround cleaning. Keeping the exchanger clean saves energy (up to double‑digit percent fuel savings). It also reduces unscheduled outages and supports sustained high octane output in alkylation. Even a single day’s throughput regained can justify the cost of additives or chemicals.

For related mechanisms, see the AIChE Annual Meeting abstract on asphaltene‑induced fouling (aiche.org). Industry journals reprint more vendor case histories (fqechemicals.com, fqechemicals.com).