Article
The hard trade-offs behind keeping marine heat exchangers clean
Preventing Biofouling and Scaling in Seawater Heat Exchangers: What Works on Ships and in Power Plants
Biofilm can cut heat exchanger efficiency by 20–50%, and its opportunity cost reaches billions. This guide summarizes continuous vs shock chlorination, electrolytic options, the role of dispersants, and antiscalants that are effective in seawater—with monitoring practices aligned with regulations.
Biofilm on pipe walls and heat exchanger tubes can cut thermal efficiency by 20–50% (www.researchgate.net). In one Aframax study, underwater cleaning that removed fouling was estimated to save ~US$2 million in fuel over five years (www.rivieramm.com). Globally, losses from marine biofouling are estimated at billions of dollars per year (www.researchgate.net).
Every percent of efficiency recovered means lower fuel use, less maintenance downtime, and lower greenhouse gas emissions (tethys-engineering.pnnl.gov) (www.rivieramm.com). The question is not whether prevention is needed, but which combination of methods is most effective and environmentally safe in seawater cooling systems.
Impact of biofouling on efficiency
Biofouling is the growth of micro/macroorganisms on heat exchanger tubes. This layer adds resistance to heat transfer, forcing pumps and fans to work harder to maintain cooling capacity. The consequences are direct: energy consumption rises, process temperatures drift, and docking/cleaning schedules become tighter (www.researchgate.net).
On ships, best practice often starts with the inlet screen. The use of coarse screens at the intake has proven fundamental; automatic screen systems help remove debris continuously before the water reaches the heat exchanger.
Chlorination: continuous vs shock
Chemical antifoulants (biocides) are the backbone of biofouling control. The oxidant of choice is chlorine because it has a broad kill spectrum; chlorine/hypochlorite reacts with bromide in seawater to form hypobromous acid, producing multiple oxidants that attack microorganisms and detritus.
Two regimens are used: low-level continuous injection and occasional high-dose shock. A continuous dose of 0.5–2 mg/L (mg/L = milligrams per liter) free chlorine at the intake maintains an environment unfriendly to algae and bacteria; a periodic dose of about 5–20 mg/L for several hours can be applied near the heat exchanger for purging (www.scribd.com). Its advantage: continuous chlorine (usually 1–2 mg/L) suppresses stable biomass, ensuring screens and tubes remain relatively clean (www.scribd.com).
However, chemical consumption increases, handling costs rise, and the risk of discharge to the environment grows. More critically, many macrofoulers (e.g. mussels, barnacles) detect the oxidant and close tightly; a brief chlorination pause of 30–60+ minutes allows shelled organisms to “reoxygenate” and survive. In practice, low-level continuous dosing often fails to eradicate hard macrofouling.
Shock chlorination (10–50 ppm; ppm = parts per million) for several hours has proven more effective at penetrating shells and sterilizing larvae, according to the experience of the Navy and power plants (www.scribd.com). Side effects: the system must be isolated/suspended, strict safety controls are required, and there is a corrosion risk because hypochlorite, HOCl (hypochlorous acid), and ClO₂⁻ form; corrosion inhibitor consumption increases and the potential for pitting is present. Regulatory trends are tightening residual chlorine in the sea: new guidance calls for <12–18 µg/L (micrograms per liter) free chlorine at the shoreline to protect 95–99% of biota (info.awa.asn.au). As a result, modern programs reduce the chlorine discharge footprint.
On ships, injection accuracy is important for both regimens; using a dosing pump makes it easier to control chemical feed at the target level.
Electrolytic alternatives on ships
“Onboard” electrolytic systems offer a safe hybrid. The electro‑chlorinator uses a seawater electrolyzer with MMO (mixed metal oxide)-coated electrodes to generate chlorine in situ, converting seawater chloride into HOCl/Cl₂ on demand. This removes the need to carry liquid chlorine/bleach—improving safety and reliability—and automatically adjusts production to the flow rate.
The chemistry is identical to that of bulk hypochlorite, and industry studies report effective control of micro/macro‑fouling: seawater electrolysis produces broad-spectrum oxidants that kill bacteria, algae, and shellfish in the water and prevent their attachment. Power demand ranges from 0.1–0.5 kWh/m³ of treated water; on ships, electricity is often cheaper and safer than transporting tons of chlorine. Practical implementations often use electrochlorination units to generate chlorine from brine on site.
Another electrolytic method is the impressed‑current sacrificial‑anode method. DC current is applied to copper/aluminum/iron anodes in the circuit, dissolving the metal and releasing Cu²⁺/Al³⁺ that are toxic to settling organisms and inhibit biofilm at the site (corrosion-group.com). An added benefit is local cathodic protection. The resulting ion concentration is relatively low (about ~0.1–1 mg/L Cu²⁺), so it is best for prevention—not “heavy cleaning”—with low maintenance (corrosion-group.com).
Non‑chemical methods and their role
Ultrasonic, plasma, and UV irradiation have been tested for fouling control; however, capital cost and uncertain long-term effectiveness limit widespread adoption. Thermal shock (hot-water recirculation) is effective against shellfish, but it cuts cooling capacity. In practice, electrolytic methods—chlorine generators or anode systems—are the most practical “chemical‑free” alternative on ships, and they can complement each other (e.g., an electrolytic chlorine generator paired with low-dose copper ions). For UV applications, integration of ultraviolet systems is usually considered on the relevant lines.
Dispersants for deposit control
Dispersants and clarifiers are non-biocide treatment aids made of organic polymers (polyacrylates, polymethacrylates) that keep particles, slime, and small organisms suspended so they do not settle on heat-transfer surfaces (bluereef.co.za) (bluereef.co.za). Polyacrylate dispersants adsorb fine particles, impart the same charge so they repel one another and stay suspended (bluereef.co.za) (bluereef.co.za).
In one industrial example, adding a bio-dispersant to a seawater recirculation system “effectively cleans and disperses heavily fouled systems, restoring flow and clarity” (www.rxmarine.com). A typical continuous or slug dose is about ~0.5–2 mg/L; it is non-corrosive, but adds organic load (potential microbial food), so caution is needed. Specialty dispersant formulations are available in the dispersant chemicals line for cooling water programs.
Operating and monitoring practices
Many operating regimes combine methods: continuous low-level electrolytic chlorination for slime, plus a shock dose once per shift when macrofouling risk is high. Chlorine or redox residual must be monitored to ensure the target is met (e.g. maintaining ~0.5 mg/L HOCl). For general biocide use, the biocides catalogue is the reference for programs that suppress biofilm without burdening operations.
Environmental policy is the guide: Indonesia—as an IMO member—ratified the 2001 AFS Convention, which bans organotin-based coatings (peraturan.bpk.go.id), so every antifouling discharge (including internal biocides) is subject to oversight. Modern programs are shifting to in-situ generation (electrolysis) and biodegradable dispersants.
Antiscalant chemistry in seawater
Seawater carries high hardness and alkalinity—typically 400–500 mg/L Ca²⁺ and >1000 mg/L Mg²⁺—so scaling is a major risk. The most common scales in seawater heat exchangers are CaCO₃ (calcium carbonate) and CaSO₄ (calcium sulfate) (www.chemicalprocessing.com). As cycles of concentration increase, calcium salts crystallize on tube walls and restrict flow. Antiscalants (threshold inhibitors) prevent this by binding scale-forming ions, disrupting crystal growth, or keeping crystals small and dispersed.
Historically, phosphorus-based inhibitors—polyphosphate and phosphonate—were the mainstay: hexametaphosphate (polyphosphate), HEDP, ATMP, and PBTC effectively disrupt CaCO₃/CaSO₄ nucleation at low doses (<5 mg/L), allowing operation at moderate cycles (www.chemicalprocessing.com). Regulatory pressure is increasing because discharged phosphate can trigger algal blooms in coastal waters (www.chemicalprocessing.com). The Indonesian trend follows IMO standards, so many operators avoid high-phosphate chemicals unless necessary.
Phosphorus-free polymer inhibitors are increasingly popular: acrylate/maleate copolymers, sulfonated acrylic polymers, and polyaspartate—working through a combination of threshold inhibition and dispersion. Many blends combine a low dose of phosphonate (e.g. HEDP) with acrylate to broaden the spectrum (CaCO₃, CaSO₄, SiO₂). New formulations (e.g. polyether phosphate‑ethylene carboxylate; FEUs) raise the cycles limit in seawater beyond that of pure phosphonates. Modern programs reach cycles of concentration of ~3.0–3.1—about twice the reuse of the old ~1.5-cycle scheme—which means saving nearly 50% of makeup flow and pump energy (www.chemicalprocessing.com).
For practical applications, antiscalant programs are consumed continuously to maintain a residual of 0.5–5 mg/L (depending on hardness).
Dose design and environment
Occasionally, “slip‑stream” softening is used—e.g. raising CO₂ or adding acid—to maintain bicarbonate solubility; but on ships, operators generally rely on antiscalants and manage cycles conservatively. In practice, Fourier analysis of scaling risk (e.g. Langelier Saturation Index; a saturation index as an indicator of deposition tendency) helps determine the inhibitor strength required. Seawater cooling systems rarely require a separate corrosion inhibitor because nickel or titanium alloys are usually resistant; the chemical focus is on scale and bio control (www.chemicalprocessing.com).
Environmental note: phosphonates hydrolyze slowly and can eventually release phosphate nutrients (www.mdpi.com). Many “eco‑friendly” inhibitors are partially biodegradable. Using non-phosphorus inhibitors prevents algal blooms and avoids potential future bans (www.chemicalprocessing.com) (www.chemicalprocessing.com). In Indonesian or sensitive waters, verify that the antiscalant meets local effluent quality standards; the Kementerian Lingkungan Hidup total phosphorus limit is generally well below 0.5 mg/L.
Program summary and ROI
A robust cooling program usually combines: a broad-spectrum dispersant/antiscalant package (often a lab-tested polyacrylate + phosphonate premix) at the recommended dose, cycles kept within the chemistry's capability, and a periodic cleaning schedule (pigging/chemical cleaning) based on pressure drop or heat transfer performance monitoring. Digital saturation monitoring (pH, conductivity) can optimize inhibitor feed in real time (www.chemicalprocessing.com). At one facility, blowdown and water costs were cut in half by raising cycles from 1.7 to ~3.1 using an advanced inhibitor (www.chemicalprocessing.com) (www.chemicalprocessing.com).
When weighing chemical costs against benefits, those figures speak for themselves: less downtime and lower fuel use, with the added benefit of compliance with environmental standards such as IMO/MARPOL for biocide discharge. On the procurement and preparedness side, a rental unit for emergency treatment solutions can be an option when the main system needs isolation for shock chlorination.
References and source metadata
Sources: peer‑reviewed studies, industry data, and government reports.
- Mathew N. et al., EcoDesign and Sustainability II (Springer, 2020) (tethys-engineering.pnnl.gov).
- “How to achieve a ‘clean’ fuel saving of US$2M between dry dockings”, Riviera Maritime (news content hub) (www.rivieramm.com) (propulsion case study).
- “Antifoulants and dispersants: How they are used in water treatment”, Blue Reef detail site (Benoni, South Africa; Apr. 22, 2025) (bluereef.co.za) (bluereef.co.za).
- “Electrolytic Antifouling”, Corrosion Group (Stavanger, Norway; webpage) (corrosion-group.com).
- I. Wallis & S. Chidgey, “New Guidance Values for Chlorine in Marine Waters”, Water e-Journal 8(1) (AWA, 2021) (info.awa.asn.au) (info.awa.asn.au).
- Wright R., “Improve Treatment of Seawater for Cooling”, Chemical Processing (Jul. 29, 2020) (www.chemicalprocessing.com) (www.chemicalprocessing.com).
- Indonesian President Regulation No. 66/2014 (ratifying IMO’s 2001 “Harmful Antifouling Systems” Convention) (peraturan.bpk.go.id).