Article
The refinery workhorse turning “sour water” into reusable supply — and savings
The refinery workhorse turning “sour water” into reusable supply — and savings
Refiners are redesigning sour water stripping units to reach sub-ppm H₂S and low-ppm NH₃ and to cut steam use. They then send the water back to crude desalting to save money. The same units are becoming the first line for meeting ammonia-N and sulfide limits.
Hydrotreaters and reformers produce "sour water". This wastewater is rich in hydrogen sulfide (H₂S) and ammonia (NH₃), and refineries must clean it before reuse or discharge. Non-phenolic hydrotreating effluent is almost all NH₃ and H₂S with little CO₂ (digitalrefining.com). In practice the feed molar H₂S:NH₃ ratio is usually 0.5–0.8 (digitalrefining.com). Phenolic sour water from coker and FCC units is different. It carries phenols and cyanides that survive stripping, and it is usually kept out of reuse because of catalyst corrosion risks (bcinsight.crugroup.com).
Design targets are set by how the refinery plans to reuse or discharge the water. Bottoms usually aim at ≤1 mg/L H₂S and ≤10 mg/L NH₃ (mg/L = milligrams per liter) (bcinsight.crugroup.com). Many plants in the field accept NH₃ at ~30–80 ppmw (ppmw = parts per million by weight) and drive H₂S down to essentially “undetectable” levels (<0.1 ppmw) (digitalrefining.com). These figures are roughly aligned with Indonesian PermenLH limits near ~10 mg/L ammonia–N and 1 mg/L sulfide (bcinsight.crugroup.com).
Sour water feed and pretreatment
Typical sour water arrives around 30–40 °C. It is degassed and oil‑skimmed, then pumped to the sour water stripper (SWS). Removing free oil before the column is standard practice. It avoids fouling and reliability problems. Refinery guidance flags oil contamination as a cause of capacity reductions and flaring upsets (pall.com). Upstream physical separation systems such as an API stage or screens can be packaged as primary oil and solids removal. Free oil is usually polished to low ppm with oil removal units.
Column design and steam duty
In the column, steam heats the water to boiling (~115–125 °C). This strips H₂S and NH₃ into the vapor. In a conventional reboiled design, lifting from ~32 °C to ~120 °C needs about 16 wt% steam. That is roughly 1.3–1.4 lb steam per gallon of bottom water (≈0.15 kg/L). This is a typical steam‑to‑water ratio for SWS service (digitalrefining.com).
Overhead gases (acid gas plus NH₃) go to the sulfur recovery unit’s thermal reactor (also called a Claus incinerator). There the residual H₂S/NH₃ are combusted before sulfur recovery (bcinsight.crugroup.com).
Direct steam vs. reboilers
Modern designs simplify the heat supply. Circulating‑thermosyphon or direct injection heaters can act as a “kettle” reboiler (pdfcoffee.com). Roughly 50% of refineries now inject low‑pressure steam directly into the stripper bottoms and abandon the kettle reboiler (pdfcoffee.com).
Direct injection adds about 10–12% extra water flow (from condensed steam). It eliminates reboiler tube fouling and simplifies the flowsheet (pdfcoffee.com). Recent SWS columns usually have 35–45 real trays. The overall vapor–liquid separation efficiency is 25–45% per tray (digitalrefining.com). Simulation shows that increasing trays (for example 18 to 32) can cut steam by ~20% (pdfcoffee.com). However, real tray efficiencies remain modest.
pH strategy and dosing control
pH control shapes which contaminant strips best. Ideally, a two‑stage system uses a low‑pH column (<5) to liberate H₂S (limiting HS⁻ formation) and a high‑pH column (>10) to strip NH₃ (limiting NH₄⁺ formation) (yokogawa.com). In practice, most refineries run a single stripper at pH ~7–9 (usually ~8) as a workable compromise (yokogawa.com). Caustic or CO₂ trims are metered with dosing pumps to hit setpoint in the feed or bottoms.
Steam injection is usually counter‑flow with internal reflux (a top‑tray pump‑around), not an external reflux loop. Therefore the design is simpler (digitalrefining.com).
Bottoms quality and reuse options
Well‑designed strippers meet bottoms targets of ≤1 ppm H₂S and ≤10 ppm NH₃ (bcinsight.crugroup.com). In the field, NH₃ is harder to strip than H₂S. Therefore operators usually accept ~30–80 ppmw NH₃, while H₂S is essentially nil (digitalrefining.com). Bottoms are cooled by feed/effluent exchange and coolers before they go off‑plot.
Non‑phenolic stripped water is usually reused as process water. A common path is once‑through crude desalter wash. Some sites remove the old wash tower and use warm SWS bottoms directly in crude units (digitalrefining.com, bcinsight.crugroup.com). Hydrotreater trains also reuse their own stripped wash water.
The economics are real. One refinery blended about 33% SWS reuse (15% to a hydrocracker wash, 18% to crude desalter wash) with no operational upsets. It saved roughly $1 million in one year of boiler‑feed water costs (watertechonline.com). At Saudi Aramco’s Ras Tanura, providing 50% stripped sour water in crude wash gave stable water quality and large cost savings. Monitoring showed the SSW performed as well as 100% fresh makeup under the site’s conditions (watertechonline.com, watertechonline.com).
Segregation of phenolic streams
Only non‑phenolic sour water is usually recycled. Phenolic sour water (from coker/FCC) carries dissolved organics: phenols, cyanides, heavy oils. These stay in the water even after stripping. They harm catalysts and upset boilers. Therefore this water goes to full effluent treatment (bcinsight.crugroup.com). Grassroots designs usually install separate SWS trains for phenolic and non‑phenolic streams. Only the non‑phenolic bottoms are recycled (bcinsight.crugroup.com).
Polishing before reuse or discharge
Even after stripping, bottoms can carry tens of mg/L NH₃ (largely as NH₄⁺ at pH ~8) and non-volatile impurities. For wastewater plants, refineries rely on nitrifying biology. Many use activated sludge systems to oxidize NH₄⁺ to nitrate. Some sites add pre-aeration or an air-strip column to degas NH₃ before the bioreactors.
Traces of oil and hydrocarbons are removed ahead of the SWS or in polishing. Therefore the WWTP receives minimal free oil (pall.com). A compact flotation stage is common, such as a dissolved air flotation unit. It removes suspended solids and oils before the water is blended with other effluents.
Refractory organics can still be high. Analyses of stripped sour water report dissolved organic carbon around 500–1000 mg/L and a low BOD/COD ratio (~0.27). This means the water breaks down poorly in biological treatment (scielo.br). Oxidation processes such as UV/H₂O₂ (hydrogen peroxide activated by ultraviolet light) removed 90–95% of DOC in tests (scielo.br). In one case, pairing these processes with modest pretreatment, for example reducing turbidity with a sand and silica filter, made the water usable as cooling‑tower makeup (scielo.br). UV reactors such as ultraviolet systems provide the irradiation stage for UV/H₂O₂ trains.
Before biological treatment, pH is usually adjusted from 8–10 toward neutral (using CO₂ or acid) to optimize nitrification. Many refineries meter these trims with chemical dosing pumps.
Standards and plant integration
Local limits drive final polishing. Indonesian petrochemical standards (PermenLH) usually set sulfide (H₂S) near ~1.0 mg/L and ammonia–N at ~5–10 mg/L (pengolahanlimbah.com). SWS units are designed so their effluent comfortably meets H₂S <0.1–1 mg/L and NH₃ ~5–10 mg/L (digitalrefining.com, bcinsight.crugroup.com). The main wastewater plant then handles the residual contaminants (for example, traces of phenol or oil) via air stripping, biological oxidation, and final polishing (bcinsight.crugroup.com, scielo.br).
Performance, steam economy, and payback
Simplified SWS designs are now common. They use direct steam, no external reflux and simple trays (pdfcoffee.com, pdfcoffee.com). Done well, a unit uses on the order of 0.15–0.20 kg steam per liter of sour water (~16% by weight). It targets <1 ppm H₂S and ~10 ppm NH₃, and this sets up large reuse and cost savings (digitalrefining.com). Good stripping also avoids upsets, from overloaded SRU incinerators to stressed wastewater plants. It also makes reuse programs possible, and these have delivered nearly $1 million/year in savings (watertechonline.com).