WhatsApp

Biological digestion

Biological Wastewater Programme

Updated

Industrial biological wastewater programmes for load, biomass, aeration, nutrient, and bioaugmentation diagnosis, verified by trends before dose changes.

Biological Wastewater Programme

Discuss the application.

Send the application, operating conditions and the result you expect. Our team will discuss the options with you.

Ask about this product

or use the contact page

Biological wastewater treatment needs stable biomass, retention time, aeration, nutrients, pH, temperature and solids separation to treat biodegradable organic load. Evaluate supplemental bacteria, enzymes or nutrients only after you have reviewed the incoming load, biomass condition, oxygen supply and potential toxicity together.

PT Beta Pramesti Asia, through beta.co.id, supports industrial wastewater treatment in Indonesia with process evaluation, Biological Booster for bioaugmentation, biological bacteria and nutrients, aerobic and anaerobic systems, SBR, MBBR, MBR, dosing and monitoring. This page helps buyers tell an operating correction apart from a supplemental-product requirement.

Which biological-process upset should be checked first?

Diagnosis should use several days of trends under comparable process conditions. One COD result, sludge colour or odour is not enough to define the cause or a product dose.

Operating symptomData to reviewResponse to evaluate
Rising effluent COD/BODFlow and load, COD/BOD ratio, pH, temperature, DO/ORP, retention time, recycle, and production changesStabilise load/equalisation, aeration, pH, and sludge age before assessing bioaugmentation
Weak floc or sludge washoutMLSS/MLVSS, SVI or settling test, clarifier blanket, RAS/WAS, filaments, and hydraulic loadCorrect solids separation and sludge control; test coagulant/flocculant only when it fits the process objective
Slow biomass recovery after an upsetToxicant history, salinity, temperature, solids loss, microscopy, and OUR/SOUR trends where availableRemove the inhibition source, restore conditions, then test a bacterial culture against a control
Suspected nutrient deficiencyBiodegradable COD/BOD, nitrogen, phosphorus, alkalinity, and actual consumption from the same periodConfirm deficiency before adding biological nutrients; avoid a universal ratio without data

The U.S. EPA Process Control Manual for Aerobic Biological Wastewater Treatment Facilities treats operating records, system observations and laboratory data as one process-control basis. That principle supports diagnosis. Effluent and acceptance targets still follow the facility permit, design and procedure.

Biological product candidates

BETAGARD 5300

Enzyme bacteria for wastewater treatment plant

BETAGARD 5300 is an enzyme/bacteria product candidate for evaluation in industrial and domestic wastewater treatment. Suitability, dose, storage and process response should follow the current TDS/SDS and a controlled site trial.

BETAGARD 5310

Enzyme bacteria for wastewater treatment plant

BETAGARD 5310 may be evaluated for streams with particular organic characteristics after the source, load, biomass condition and upset cause have been defined. Use a baseline and control to assess the response.

BETAGARD 5330

Bacterial cultures

BETAGARD 5330 is a bacterial culture that may be evaluated for bioaugmentation. It does not replace corrections to aeration, pH, solids retention, solids separation or toxicant control.

How should a biological product be trialled?

  1. Establish the baseline for load, effluent quality, DO/ORP, pH, temperature, MLSS/MLVSS, settling, sludge wasting, and product consumption.
  2. Confirm the problem and the operating corrections already made. Do not change several primary variables at the same time.
  3. Verify the product, batch, TDS/SDS, storage, activation or dilution where needed, injection point, and dose basis.
  4. Run a controlled trial with an agreed period and acceptance criteria. Record improvement, no change, and deterioration.
  5. Accept the programme only when trends improve without transferring the problem to the clarifier, sludge, odour, nutrients, or disposal route.

For process selection, compare activated sludge, MBBR, SBR, and MBR. A biological product does not replace verification of the main process capacity.

Buyer questions

When is supplemental bacteria worth testing?

Test bioaugmentation after you have checked inhibition, biomass loss, aeration, pH, temperature, nutrients and solids separation. A start-up, a recovery after an upset or a new load can justify a trial. However, the results need a clear baseline.

Does every biological plant need supplemental nutrients?

No. Add nutrients only when influent and biomass data from the same period show a deficiency against the biodegradable load. Too much nitrogen or phosphorus adds effluent load and cost.

Which data should be sent for an evaluation?

Send the process diagram, volume and flow, influent and effluent analyses, DO/ORP, pH, temperature, MLSS/MLVSS, settling and SVI, RAS/WAS, aeration, sludge age, product consumption, upset history and permit target through the Beta Pramesti Asia contact page.