WhatsApp

Oilfield chemicals

Oilfield Corrosion Inhibitor Series

Updated

Oilfield corrosion inhibitor for water and gas production systems, with field-adjusted injection from wells and pipelines to process equipment in Indonesia.

Oilfield Corrosion Inhibitor Series

Discuss the application.

Send the application, operating conditions and the result you expect. Our team will discuss the options with you.

Ask about this product

or use the contact page

An oilfield corrosion inhibitor reduces metal loss and pitting. It does this by forming a protective film on surfaces exposed to corrosive production fluids. PT Beta Pramesti Asia supplies BETAFLOW CR 501 for water-bearing systems and BETAFLOW CR 551 for gas-field service. We select the product and the dose from fluid chemistry, metallurgy, flow and field corrosion data.

The BETAFLOW CR 500 Series corrosion inhibitor holds a TKDN certificate with a value of 53.04%. See the BETAFLOW TKDN certificates.

Which BETAFLOW Corrosion Inhibitor Fits the System?

BETAFLOW CR 501 and CR 551 serve different production conditions. CR 501 is formulated for oil and gas systems exposed to water, carbon dioxide (CO2), hydrogen sulfide (H2S), and organic or inorganic acids. CR 551 is an amine-based option for gas-field equipment exposed to H2S and acids. A field trial is still needed because corrosive species, water cut, temperature, velocity, and injection location affect the dose you need.

Selection pointBETAFLOW CR 501BETAFLOW CR 551
Primary serviceWater-bearing oil and gas production systemsGas-field production systems
Protected assetsWells, pipelines, and process equipmentWells, pipelines, and process equipment
Corrosion drivers stated for the productH2S, CO2, and organic or inorganic acidsH2S and organic or inorganic acids
ApplicationFlush treatment or continuous injectionFlush treatment or continuous injection
Starting field range10-45 ppm of produced fluid10-100 ppm of fluid rate

The ranges above are starting points from the product specifications. They are not fixed operating setpoints. Confirm the actual dose through field optimisation and corrosion monitoring.

BETAFLOW CR 501 Protects Water-Bearing Production Systems

BETAFLOW CR 501 is a water-soluble, film-forming corrosion inhibitor for oil and gas production systems. It protects pipelines and process equipment against metal deterioration and pitting from H2S, CO2 and acidic fluids.

Physical formSpecific gravityWater solubilityApplicationPackaging
Yellow to dark brown liquid1.10-1.30SolubleFlush or continuous injection; optimise from a 10-45 ppm starting range200-litre drum

BETAFLOW CR 551 Protects Gas-Field Equipment

BETAFLOW CR 551 is an amine-based, water-soluble corrosion inhibitor for gas-field production equipment. Its protective film is intended to reduce metal deterioration and pitting from H2S and organic or inorganic acids. This covers the well, the pipeline and the process equipment.

Physical formSpecific gravityWater solubilityApplicationPackaging
Yellow to dark brown liquid0.86 ± 0.1SolubleFlush or continuous injection; optimise from a 10-100 ppm starting range200-litre drum

What Data Is Needed Before Selecting an Inhibitor?

A usable recommendation needs recent fluid and operating data. Prepare water cut, CO2 and H2S exposure, pH, chloride or salinity, operating temperature and pressure, flow rate, metallurgy, corrosion history, and the available injection point. Also state whether treatment will be continuous, batch, or a system flush.

Corrosion coupons, probes, iron counts, inspection findings and failure locations help establish the baseline. They also show whether the selected program is controlling corrosion. Chemical feed should be matched to the available dosing pump system and reviewed alongside the wider oilfield chemicals program.

Common Questions

Is an oilfield corrosion inhibitor the same as a cooling-water inhibitor?

No. This BETAFLOW CR page covers oil and gas production fluids. Recirculating cooling water has different water chemistry, metallurgy, biological activity and monitoring needs. See the separate cooling-water corrosion inhibitors range.

Can the injection rate be taken directly from the table?

No. The stated ppm values are initial field ranges. The final dosage depends on the corrosion mechanism, fluid composition, flow regime, injection location and the measured treatment response.

How can a buyer request a technical recommendation?

Send the operating and corrosion data through the Beta Pramesti Asia technical contact page. The review should confirm the service conditions, treatment method, monitoring plan, packaging and site delivery requirements.