Boiler
Boiler Oxygen Scavenger Price
Updated
Boiler oxygen scavenger price depends on product, dosage, oxygen load, boiler capacity, volume, monitoring, logistics, and support from Beta Pramesti.
Discuss the application.
Send the application, operating conditions and the result you expect. Our team will discuss the options with you.
Boiler Oxygen Scavenger Price Depends on System Load
An oxygen scavenger is a chemical product that removes the residual dissolved oxygen from boiler feedwater after deaeration, before that oxygen can cause pitting in feedwater lines, economizers and boiler tubes. When oxygen still passes the deaerator, air enters through leaks, or inspection finds active pitting, these are reasons to evaluate oxygen control and the scavenger requirement. PT Beta Pramesti Asia supplies BETAGARD 2512 and BETAGARD 2695.
Boiler oxygen scavenger price depends on the product, the evaluated dose, the oxygen load, the feedwater flow, the operating hours, the supply volume, the logistics and the monitoring scope. Compare the programme cost at the same boiler condition and the same residual target. Do not compare the price per drum alone. The programme is selected from the operating data.
Last technically reviewed: 27 November 2026.
An oxygen scavenger does not replace a deaerator. The DOE Energy Efficiency Handbook notes that a properly designed and maintained deaerator typically reduces feedwater oxygen to below 15 µg/L (15 ppb) without an additional scavenger, and that a scavenger cannot take over the deaerator’s function: above 50 µg/L (50 ppb) of feedwater oxygen, oxygen corrosion can still occur even when a scavenger is used. Product and dosage selection should consider pressure, feedwater temperature, dissolved oxygen, reaction time, pH, steam end use and residual-monitoring results.
Use the oxygen scavenger definition and boiler guide to separate deaerator performance, chemical demand, sample quality and corrosion diagnosis before you define a trial.
A comparable quotation should state the product, the dose basis, the daily demand, the pack size, the delivery location and schedule, the sampling frequency, the programme residual target and the evaluation support. Daily demand can only be calculated after the feedwater flow and the dose on an as-supplied product basis are confirmed.
When does a boiler need an oxygen scavenger?
A boiler needs an oxygen-scavenger review when oxygen remains after deaeration, when air enters through system leaks, or when inspection finds active pitting. Check the oxygen source and the deaerator performance before you increase the dosage. Adding more chemical without a diagnosis can conceal a mechanical problem.
| Operator question | Evidence to check | Next action |
|---|---|---|
| Why is pitting appearing in the feedwater line or economizer? | Dissolved oxygen, deaerator temperature and venting, pump-suction air leaks, and corrosion pattern | Correct oxygen ingress, then review the product, injection point, and scavenger residual |
| Why is the scavenger residual unstable? | Load changes, feedwater temperature, residence time, solution strength, and dosing-pump calibration | Verify feed rate, solution tank, sampling point, and test method |
| Should dosage increase during start-up or shutdown? | Lay-up procedure, boiler condition, shutdown duration, and water-test results | Use an approved start-up or lay-up procedure; do not assume the normal operating dose applies |
| Is one formulation suitable for every boiler? | Pressure, temperature, pH, metallurgy, attemperation, and steam use | Review system data and current product TDS/SDS before selecting a formulation |
How should a boiler oxygen scavenger be selected?
Oxygen-scavenger selection depends on the system, not on the active-ingredient name alone. Reaction speed, residence time, temperature, pressure, feedwater pH, decomposition products, system metallurgy and steam use decide which chemistry fits. The DOE Energy Efficiency Handbook is explicit that the decision to use a substitute scavenger or rely on sodium sulfite should only be made by those qualified to make boiler water treatment decisions.
| Selection data | Why it matters | Evidence to prepare |
|---|---|---|
| Boiler pressure and feedwater temperature | These affect reaction rate and program suitability | Operating pressure, deaerator outlet temperature, and load range |
| Dissolved oxygen before and after the deaerator | This separates a deaeration problem from the chemical-polishing requirement | DO trend, vent condition, and tests from a consistent sampling point |
| Residence time and injection point | The scavenger needs contact time before water reaches vulnerable equipment | Flow diagram, tank volume, flow rate, and dosing-pump location |
| Steam use and attemperation | Reaction products or solids must not compromise steam or process quality | Steam destination, attemperation route, and process-quality requirement |
| Chemical residual and corrosion trend | These show whether the program works without overfeeding | Defined program residual, pH, dissolved iron, and inspection records |
Sulfite or an organic scavenger: which fits?
Sulfite is the most common scavenger because it reacts quickly with residual oxygen and its residual is easy to measure in boiler water (DOE Energy Efficiency Handbook). Its limits depend on pressure and steam use. In higher-pressure boilers, generally above about 900 psig (6.2 MPa), some sulfite can break down and carry into steam, where it disturbs condensate systems and condensing turbines. Where that decomposition causes problems, a substitute scavenger, usually organic-based, can be used after evaluation by qualified personnel. The sulfite reaction also adds dissolved solids to the boiler water, so blowdown must account for it.
| Feedwater and system condition | Chemistry to consider | Reason |
|---|---|---|
| Dissolved oxygen after the deaerator still above 50 µg/L (50 ppb) | Correct the deaerator first, not the dose | A scavenger does not replace the deaerator; oxygen corrosion can still occur |
| Boiler pressure above about 900 psig (6.2 MPa) | A substitute scavenger, usually organic-based, can be used after qualified evaluation | Sulfite can break down into steam and disturb condensate systems and turbines |
| Low feedwater temperature or short contact time | Catalysed sulfite | The catalyst speeds the reaction at a lower feedwater temperature |
| Feedwater used for attemperation | Injection point other than the deaerator storage tank | DOE: other locations are preferable when feedwater is used for attemperation |
| Steam in contact with food products | Confirm the product suitability documents first | Suitability for a food facility depends on the data sheet and site requirements |
Beta’s portfolio lists BETAGARD 2512 and BETAGARD 2695 for corrosion protection and dissolved-oxygen scavenging. The final formulation, initial dosage, injection point and residual target should be confirmed against the current TDS/SDS and a system review. This page does not replace plant-specific technical recommendations.
How should daily demand and dosage be verified?
Calculate consumption from the approved as-supplied product dose, the feedwater flow and the operating hours. Do not build a stoichiometric factor from the active-ingredient name. Strength, side reactions, contact time and target residual differ by formulation. Then prove the pump output and read it together with dissolved oxygen, the programme residual and corrosion indicators.
Product demand (kg/day) = as-supplied dose (mg/L) × feedwater flow (m³/h) × operating hours ÷ 1,000. For example, 8 mg/L at 60 m³/h for 24 hours needs 8 × 60 × 24 ÷ 1,000 = 11.52 kg/day. If the actual batch density is 1.10 kg/L, that is 11.52 ÷ 1.10 = 10.47 L/day, or about 0.44 L/h in continuous operation. The 8 mg/L dose and the 1.10 kg/L density are examples. They are not BETAGARD recommendations or specifications.
| Field evidence | Result pattern | First decision before changing dose |
|---|---|---|
| DO after the deaerator is high or unstable | Scavenger residual may rise or fall with it | Check temperature, venting, pressure, air ingress, and sample quality; correct the oxygen source first |
| DO is consistent but residual is low | Product demand has risen or the residual test is doubtful | Verify solution strength, pump output, quill/check valve, reaction time, and test method |
| DO is consistent and residual is well above the site control envelope | Chemical use is high with no benefit in the corrosion trend | Hold any increase, confirm sampling, then evaluate a controlled reduction under the programme recommendation |
| DO and residual appear normal while iron or pitting worsens | One KPI does not explain the corrosion mechanism | Check pH, condensate, deposits, shutdowns, flow-accelerated corrosion, and air-ingress location |
| Pump setting looks correct but tank use does not reconcile | Inventory balance differs from stroke/duty | Run a drawdown/weighing test and check siphoning, leakage, pulsation, backpressure, and tank-fill records |
Dissolved-oxygen sampling is easily biased. Air can enter after the sample point, cooling can be uncontrolled, the sample-cell flow can change, or the instrument may not be verified. Record the time, load, sample point, sample temperature and flow, instrument and operator. Do not merge different points or methods into one trend.
For a consumption audit, check the formula against the tank mass or volume change over the same period. If the difference stays, repair the measurement or the feed system before you change the dose. The boiler chemical programme then combines scavenger control with feedwater quality, alkalinity, scale control, condensate and lay-up procedures.
What data should be sent for an evaluation?
Please prepare the following information so the review does not start with assumptions:
- Boiler pressure, capacity, load pattern and operating hours.
- Deaerator outlet temperature and feedwater dissolved-oxygen results.
- pH, conductivity or TDS, hardness, alkalinity, silica and iron.
- Makeup-water source and rate, plus the percentage of returned condensate.
- Injection point, dosing-pump capacity, solution strength and sampling point.
- Program residual target, pitting or leak inspection findings and shutdown history.
For a whole-program review, see boiler water treatment, boiler scale control, and neutralizing amines for condensate lines. Injection hardware can be reviewed through Watermart dosing pumps for water treatment.
Frequently Asked Questions
Who supplies boiler oxygen scavengers in Indonesia?
PT Beta Pramesti Asia supplies BETAGARD 2512 and BETAGARD 2695 in Indonesia as part of an industrial boiler-chemistry program. Beta reviews dissolved oxygen, deaerator performance, pressure, temperature, injection point, chemical residual and corrosion evidence before we make a final recommendation.
Can an oxygen scavenger replace a deaerator?
No. A deaerator removes most dissolved gases mechanically. An oxygen scavenger controls the residual oxygen and the oxygen load that still enters the system. If the deaerator performs poorly, correct it. Do not compensate for it only with a higher chemical dose.
Where should an oxygen scavenger be injected?
The injection point should give enough reaction time before the water reaches the economizer or boiler. It should also stay compatible with the system design. You may consider the deaerator storage section or the feedwater line. However, the final location depends on the flow diagram, pump pressure, steam use and product recommendation.
How can operators verify that the scavenger program works?
Judge performance from trends, not from one sample. Monitor dissolved oxygen, the defined program residual, pH, dissolved iron, deaerator performance, chemical consumption and pitting inspection results. Use consistent sampling points and frequencies.
How can I request a BETAGARD oxygen-scavenger evaluation?
Send operating data and water-test results through the Beta contact page. The PT Beta Pramesti Asia team can review the system before defining the product, initial dosage, injection point and monitoring plan.