Inside the chemistry that keeps HRSGs clean: ppb‑level control, AVT, and a zero‑tolerance policy on silica

beta-pramesti-asiaindustry-power-generation-combinedprocess-ccgt

Inside the chemistry that keeps HRSGs clean: ppb‑level control, AVT, and a zero‑tolerance policy on silica

High‑pressure heat recovery steam generators (HRSGs) in combined‑cycle plants depend on water purity. This is a playbook for ultra‑pure makeup and an all‑volatile treatment (AVT) program. It is written for the plant chemists and engineers who run them.

Industry: Power_Generation_(Combined_Cycle_Gas_Turbine_ | Process: _CCGT)

In modern combined‑cycle plants, a few parts per billion can decide HRSG reliability. Ultra‑pure demineralized makeup water sets the baseline. Think resistivity in megaohm·cm and conductivity down near ~0.1–0.3 µS/cm at 25 °C. Everything else is the discipline to hold it there with coordinated chemistry, metering, and monitoring.

Indonesia’s SNI 7268:2009 for high‑pressure service states the limits plainly. Feedwater conductivity must be ≤0.3 µS/cm (that is, >3.3 MΩ·cm) above ~75 bar. Silica in once‑through HRSGs must be ≤0.02 mg/L (20 ppb) (pdfcoffee.com, id.scribd.com). Those limits follow international cycle‑chemistry guidance. They also follow the operating reality. Even modest excursions, 1 ppm dissolved solids or 100 ppb silica, can cut heat‑transfer efficiency and cause premature cleanings (power-eng.com, diversey.co.id).

Plants usually run 3–5X cycles of concentration with blowdown around ~2–5%. This keeps dissolved solids from approaching saturation. That puts makeup TDS in the single‑digit mg/L range. The "de‑gassed" ion conductivity is usually ≤0.1 µS/cm. Feedwater iron stays well below 5 ppb, silica <20 ppb, and conductivity <0.2 µS/cm. These numbers follow strict cycle chemistry practice (power-eng.com, pdfcoffee.com).

Ultra‑pure makeup specifications

The target is clear: megaohm‑class water feeding the economizer. In practice, that means multistage demineralization that can deliver conductivity near ~0.1–0.3 µS/cm at 25 °C, silica at ≤0.02 mg/L in once‑through service, and ultra‑low metals. SNI 7268:2009 sets feedwater conductivity ≤0.3 µS/cm above ~75 bar. It also sets silica at ≤0.02–0.04 mg/L depending on drum usage (pdfcoffee.com, id.scribd.com).

Many power facilities install high‑recovery membrane trains. Industry literature cites a gas‑turbine HRSG that runs RO plus mixed‑bed polishing and consistently exceeds 10 MΩ·cm resistivity (≈0.1 µS/cm) (power-eng.com). Where membranes are central to the design, standardized skids such as brackish‑water RO and integrated membrane systems help keep pre‑boiler conductivity and silica under tight control.

Pretreatment and polishing train

The typical sequence is coarse media filtration → softening (if hardness is present) → reverse osmosis (to remove >90–95% of ions) → mixed‑bed polishers (cation–anion exchange) as needed, with electro‑deionization as a finishing step. Plants monitor RO permeate continuously. Conductivity is held to <1 µS/cm, and pre‑RO silica to <0.1 mg/L. Therefore the RO and polishers can deliver an order of magnitude lower at the final point (power-eng.com).

On the ion‑exchange side, many facilities standardize on demineralizers and mixed‑bed polishers to drive silica and ionic contaminants to sub‑ppb territory. EDI also gives continuous ultra‑pure production without chemical regeneration. If hardness control is needed upstream, softeners and the right ion‑exchange resins prevent scale‑forming Ca/Mg slip.

(Footnote: in practical terms, a well‑designed feedwater plant will achieve ≥90% recovery and produce only a few percent waste reject. For example, a 40,000 m³/day plant might blowdown 2–4% by volume with TDS ≤1,000 mg/L per GR82/2001 permitting.)

Any lapse shows up as deposits, sodium phosphate or silicate scale. These can raise fuel cost ~0.1–0.3% per %flow drift. Industry reports corroborate this sensitivity. They warn that even 1 ppm dissolved solids or 100 ppb silica can degrade heat transfer and force earlier cleanings (diversey.co.id, power-eng.com).

Feedwater conditioning and deaeration

Before the economizer, plants track conductivity, pH and dissolved oxygen (DO) continuously. A low-level mechanical deaerator is used only if copper alloys are present. For an all-ferrous HRSG, the deaerator vent may be throttled to retain ppm-level oxygen for AVT(O) while still driving residual oxygen very low. As a rule of thumb, feedwater O₂ after deaeration or polishing is held <20 ppb. EPRI AVT(O) specifications cite condensate-pump discharge DO ≤20 ppb and economizer inlet 5–10 ppb (power-eng.com).

Instrumentation usually includes a DO analyzer at the condensate pump and conductivity/degassed-conductivity monitors after the polisher and before the feed pump. Blowdown is adjusted to cap ionic impurities. Plants keep condensate cation conductivity at ≲0.2 µS/cm to prevent anion carryover (power-eng.com). Where condensate return needs cleanup, a condensate polisher removes transport metals and ammonia carryover after the condenser.

AVT chemistry program (ammonia, oxygen)

The boiler circuit runs all-volatile treatment, AVT (volatile chemicals only), with ammonia (or volatile amines) for [pH control and an oxygen “scavenger.”](https://beta.co.id/en/blog/inside-the-hrsg-feedwater-playbook-scavenge-oxygen-raise-ph-cut-corrosion) Under AVT, ammonia sets a mildly alkaline environment that promotes a protective magnetite film on steel surfaces. IAPWS notes ammonia as the common alkalizing agent, and amines are also used (scribd.com). Plants dose to maintain feedwater around ~9.0–9.4 pH at 25 °C. Per EPRI targets for an FFLP HRSG, they reach an LP economizer inlet pH of 9.6–10.0 (power-eng.com).

Typical ammonia targets are ~5–15 ppb NH₃ in the hottest LP economizer feed and ~30–50 ppb NH₃ at the economizer inlet. This counteracts flash‑off and holds that 9.6–10.0 pH band (power-eng.com). Plants usually meter with precision dosing pumps. They pair a neutralizing amine program with oxygen control via oxygen scavengers.

Under classic reducing AVT (AVT(R)), hydrazine follows mechanical deaeration to remove the ~7 ppb residual O₂. Legacy designs added ~20–100 ppb hydrazine to treat “any” DO as harmful (power-eng.com). However, the industry pivoted after high‑profile flow‑accelerated corrosion (FAC) failures, for example the 1986 Surry NPP pipe rupture, toward AVT(O) or oxygenated treatment. All‑ferrous HRSGs usually avoid deep reduction today (power-eng.com, power-eng.com).

In AVT(O) today, a small controlled amount of oxygen is present, sometimes added on purpose. This helps form a tenacious FeOOH layer and strongly suppresses single-phase corrosion (power-eng.com, scribd.com). If a scavenger is used, it is usually injected at the condensate pump outlet to bring DO down to <10–20 ppb (power-eng.com).

Instrumentation and trending controls

Real-time control depends on precise chemical metering and online analytics. Plants trend feedwater pH (online), oxygen/ORP or DO at feedpump discharge, and conductivity (direct and degassed) to spot excursions. A rising conductivity usually flags condenser leaks or blowdown mis-set. Action levels kick in when iron or copper exceed ~2–5 ppb, and this prompts chemistry or blowdown adjustments. Some sites add online iron analyzers to keep Fe at a few ppb.

Routine lab work checks hardness (to make sure Ca/Mg is zero), chloride, sulfate, silica and metals in feed and boiler water. Simple condensate Br⁻ or Cl⁻ tests can catch cooling-tower bleed or condenser leaks early. In HRSGs, iron coolant injection has been used to control FAC. This is low-level Fe₃O₄ colloid dosing to saturate the loop, coordinated with AVT so the iron does not go above a few ppm.

Standards, limits, and legal compliance

SNI 7268:2009 sets strict HRSG feedwater standards. DO must be ≤0.007 mg/L (7 ppb). Total Fe/Cu must be in the ~0.01–0.03 mg/L (10–30 ppb) range depending on pressure. Wood Chemistry Lab SNI table 3 shows Fe max 0.03 mg/L up to 10 MPa, and 0.01 mg/L beyond 15 MPa (pdfcoffee.com, pdfcoffee.com). Silica is likewise capped at ≤0.02–0.04 mg/L depending on drum service (pdfcoffee.com, id.scribd.com). These targets are in line with international practice. British JIS/BS recommendations put Fe and Cu on the order of 10 ppb in high‑voltage feedwater. They also match EPRI guidance for AVT(O), for example pH 9.6–10.0 and DO ≤20 ppb (power-eng.com).

Waste handling and chemical safety are regulated. Blowdown and ion-exchange regenerants must meet Government Regulation 82/2001 water-quality standards. Chemicals designated B3, including hydrazine, fall under MOEF Regulation 9/2024. Producers of B3 waste must manage it, treat it, and hand it off to licensed facilities (hhp.co.id). Many plants have eliminated hydrazine because of its toxicity. If it is used, it is fed by closed-loop injection with continuous leak detection. Any spent resin or washwater goes to a licensed B3 waste facility (hhp.co.id). Ammonia is tracked for steam-cycle carryover. It is usually removed after the condenser by polishing, so that nitrate is not released.

We check compliance by routine sampling per SNI 7268 (for example conductivity, pH, hardness, Fe, Cu, Na, SO₄, Cl, SiO₂ of feed and boiler water) (pdfcoffee.com, pdfcoffee.com). Routine upkeep of the pre‑boiler plant (filters, polishers and chemical metering) usually relies on standard spares. Operators usually stock consumables for ion exchange and membranes alongside plant chemicals. However, specific inventories vary by site.

Measured outcomes in service

AVT(O) holds feedwater pH near ≈9.8 and O₂ at about 10 ppb. Under these conditions plants report feedwater iron ≤2 ppb and steam-cycle copper below detection. That is roughly 10× lower metal transport than under older AVT(R) regimes (scribd.com). Deposits from chlorides and sulfates on turbine blades are essentially gone, so stage efficiency stays within design. Each 10 ppb Fe in high-pressure steam can drop turbine efficiency by ~0.01–0.02% (power-eng.com).

Case histories also point to reliability gains: shifting from phosphate programs to AVT in high‑pressure units reduced forced outages from water chemistry by >70% over five years. For HRSG operators, the message is consistent—[ultra‑pure makeup plus optimized AVT chemistry](https://beta.co.id/en/blog/inside-the-ultra-pure-water-playbook-keeping-high-pressure-hrsgs-alive) is a core enabler of high availability and long tube life (power-eng.com; power-eng.com).

Sources and citations

IAPWS Technical Guidance (2015) defines AVT and target ranges, including AVT(O) practice and volatile alkalizing agents (“usually ammonia”) (scribd.com, scribd.com). EPRI targets summarized by Buecker give practical limits such as pH 9.6–10.0 and DO ≤20 ppb (power-eng.com). SNI 7268:2009 (Indonesia) sets feedwater DO ≤0.007 mg/L, Fe ~10–30 ppb and silica limits to ≤0.02–0.04 mg/L. The cited tables give the pressure‑tiered maxima (pdfcoffee.com, pdfcoffee.com, id.scribd.com). The summary of regulatory obligations on B3 wastes comes from MOEF Reg. 9/2024 (hhp.co.id).

Product integration notes

Where plants seek standardized hardware, the research above maps directly to proven categories: reverse osmosis for primary demineralization, demineralizers and mixed‑bed polishers to push silica and TDS to ppb levels, and EDI for continuous ultra‑pure production. For hardness control and resin management, softeners and ion‑exchange resins align with the “softening (if hard feed)” requirement. In chemistry dosing, dosing pumps support precise pH and oxygen control via neutralizing amines and oxygen scavengers. On the return side, a condensate polisher supports the low‑metal, low‑ammonia condensate targets described above.