Refineries’ New Water Math: Inside the API→DAF→Bio→O₃-AC Train Hitting COD ~50 mg/L

beta-pramesti-asiaindustry-refineryprocess-wastewater-treatment

Refineries’ New Water Math: Inside the API→DAF→Bio→O₃-AC Train Hitting COD ~50 mg/L

A central wastewater treatment plant for a modern refinery uses gravity, flotation, biology and polishing to bring effluent down to COD ~50 mg/L and TOC ~20 mg/L. The plant has several barriers because the feed carries oil, ammonia and shock loads. It is built to meet the national discharge limits.

Industry: Refinery | Process: Wastewater_Treatment

Refinery wastewater changes all the time. It carries hydrocarbons, suspended solids, phenols, sulfides and ammonia, and now and then a slug of crude. The modern answer is a central wastewater treatment plant (WWTP). It puts primary physical and chemical steps, secondary biological oxidation and a tertiary polish in one line, then automates the whole plant.

In Indonesia, PermenLH 19/2010 sets refinery effluent limits at BOD₅ ≤ 80 mg/L, COD ≤ 160 mg/L, oil & grease ≤ 20 mg/L, sulfide ≤ 0.5 mg/L, and NH₃–N ≤ 8 mg/L (id.scribd.com). In practice, many plants aim lower. They target a final COD of about 50 mg/L and a TOC of about 20 mg/L. This keeps them compliant when the feed varies (www.nature.com).

Treatment train fundamentals and targets

A typical refinery WWTP begins with influent screening and grit removal to protect downstream nozzles and pumps. Simple choices here, such as an automatic screen or a headworks package, can prevent early fouling. The core train follows: gravity oil–water separation (API or corrugated plates), dissolved air flotation (DAF), biological oxidation/nitrification, and a tertiary polish with filtration, membranes, adsorption, or oxidation.

Recent case studies give these figures. API or CPI units remove about 60–80% of free oil. DAF with coagulants removes 80–90% of oil and TSS and can cut COD by about 75% (www.mdpi.com, www.mdpi.com). Secondary biological systems remove dissolved organics (COD usually below 90%) and more than 90% of ammonia, if the sludge age and dissolved oxygen are adequate. Integrated A/O+MBR systems have reported about 94% removal of COD, BOD and NH₄–N (www.nature.com, www.mdpi.com). Tertiary polishing (ozone, activated carbon or membranes) brings final COD to about 50 mg/L and TOC to about 20 mg/L. Free oil can fall below 1 mg/L with UF or MBR (www.nature.com).

Primary oil–water separation (API/CPI)

API separators (American Petroleum Institute standard) are gravity tanks. They are sized so oil droplets of ≥~150 μm rise under laminar flow governed by Stokes’ Law, usually with 30–60 minutes retention time. They have no submerged moving parts and very low energy draw, so they cope with large spills. However, they can struggle with emulsified droplets, floor sludge, and keeping the hydraulics quiescent (sumiowater.com, sumiowater.com, pt.scribd.com). For 1,000 m³/h, a conservative design could allocate ~3,000 m² of footprint (for example, 8 channels of 40 m × 4 m). Large plants usually need multiple parallels (pt.scribd.com). Many sites add compact modules like an oil-removal unit to the skimming when space or spill risk dictates.

Corrugated plate interceptors (CPI) cut the footprint by adding inclined plates that shorten the rise distance. In the same 1,000 m³/h case, the CPI area is about 1,250 m² against about 3,000 m² for API, with similar free-oil removal. Operators need to manage moving scrapers and clogging by waxy solids. Therefore a CPI usually sits after a coarse tank or screen (pt.scribd.com).

DAF design, chemistry, and energy

Dissolved air flotation (DAF) injects micron‑scale bubbles. The bubbles attach to fines and emulsified oil, and lift them for skimming. Coagulant dosing works at pH ~5–6, for example with poly‑aluminum sulfate. Air saturator pressures of 0.3–0.5 MPa then remove more than 80% of residual oil, grease, COD and TSS (www.researchgate.net). Full‑scale data show API+DAF trains remove ~90% of oil and solids and ≈75% COD. Oil is often driven to <50 mg/L (www.mdpi.com, www.mdpi.com). In design, conventional DAFs handle 500–2000 m³/h and use upflow velocities of 1–2 m/h. They keep superficial rise ~1 m/h to maximize bubble attachment. Recirculation power typically runs ~0.1 kWh/m³ (www.mdpi.com). To de‑risk the step, we use a skid like a DAF unit, commercial coagulants and flocculants, and an accurate dosing pump for pH and polymer control.

DAF must be sized for peak oil loads. It also needs automated skimmers and scum troughs to prevent re‑entrainment (www.mdpi.com, www.researchgate.net). One cited case combined API+DAF to achieve ~90% oil and solids removal and ~75% COD reduction (Dizayee, 2023, www.mdpi.com).

Secondary biological treatment choices

After primary separation, biology removes dissolved organics and nitrogen. Activated sludge (AS) systems keep sludge retention time (SRT) long, 10–20+ days, for slow‑growing nitrifiers. Dissolved oxygen (DO) stays around 2–3 mg/L. Typical refinery influents carry COD in the 500–2,500 mg/L range. A well‑run AS removes >85–95% BOD and 80–95% NH₄–N when SRT and DO are adequate (www.nature.com). As a platform choice, an activated-sludge system is still the workhorse for many refineries.

Sequencing batch reactors (SBRs) use fill‑and‑draw cycles to handle variability and combine nitrification and denitrification in one tank. Fixed‑film options like MBBR/BAF carry more biomass, so they resist shock loads. Membrane bioreactors (MBRs) keep all biomass behind an ultrafiltration (UF) barrier and run at MLSS up to 15–20 g/L to stabilize nitrification. One HF‑MBR on real refinery wastewater reported 82% COD and 89% BOD₅ removal (www.mdpi.com). For flexibility, the options are an SBR train, an MBBR retrofit, or a high‑efficiency MBR platform.

Kinetics, configuration, and ammonia control

Designers usually load at 0.2–0.6 kg BOD/kg MLSS/day with HRT of 6–12 hours and SRT >15 days. Multi‑stage trains, A²/O (anaerobic/anoxic/aerobic) or anoxic→aerobic (A/O), sequence carbon oxidation and denitrification. They usually start with aerobic removal of 50–80% BOD, then an anoxic stage using internal carbon/recycle, then a final aerobic nitrification. Yang et al. reported 75% COD and 94% NH₄–N removal by combining microaerobic hydrolysis–acidification with anoxic/oxic AS (www.nature.com).

Ammonia spikes can derail nitrification. A proprietary Indonesian concern (IKORC) found that NH₄–N above ~70 mg/L caused failure unless pretreated. It recommended upstream air‑stripping where needed (pubs.acs.org). Where tertiary polishing of nitrogen is needed, plants may add a final denitrification step or deploy ion‑exchange resins. Integrating an N/P removal module can safeguard against eutrophication drivers.

Solid–liquid separation after biology

Downstream of the bioreactors, clarifiers or membranes separate the biomass. Sludge recycle keeps the MLSS up and wasting controls the SRT. Sites with little space use media‑rich processes (for example IFAS/MBBR) to keep MLSS high without oversized clarifiers. Compact settlers such as a lamella settler help cut the footprint by up to 80% compared with conventional basins.

Tertiary filtration and adsorption

Polishing turns to trace organics, color, clarity and pathogens. Multimedia filters run at 1–5 m³/m²·h and knock down the remaining suspended solids. Paired with granular activated carbon (GAC), they strip dissolved hydrocarbons and phenols. Plants usually specify media such as sand/silica and use activated carbon beds after the biological treatment.

Membrane filtration tightens the barrier. UF/MF can push turbidity below 0.1 NTU and, in some cases, total oil under 1 mg/L. Pairing UF with MBRs gives reuse-ready clarity (www.mdpi.com). A standalone ultrafiltration module usually works as pretreatment and as the final barrier in water reuse trains.

Advanced oxidation and disinfection

Ozone (O₃), UV/H₂O₂, Fenton, or photocatalysis target refractory organics (for example, phenols, PAHs). Ozonation stages usually dose ~5–20 mg/L with several minutes’ contact, followed by quenching or biofiltration to address by‑products such as bromate. An O₃ + activated carbon (O₃‑AC) finish has delivered COD ~50 mg/L and TOC ~20 mg/L in full‑scale practice (www.nature.com). Disinfection, usually UV or chlorination, is applied after substantial clarification. UV doses ≥30 mJ/cm² provide pathogen control, with equipment options like a UV disinfection unit.

Reuse ambitions and membranes

Refinery reuse is growing. UF/MF trains can meet potable reuse benchmarks for many parameters when they are paired with disinfection (www.mdpi.com). NF/RO is used when salt and trace ion control is needed, or to push COD < 20 mg/L and TOC < 5 mg/L. Designers make it part of an integrated membrane system. Where brackish TDS dominates, a brackish-water RO stage or a hardness‑targeted nano-filtration bridge can complete a ZLD‑oriented stack.

Design targets and achieved performance

New WWTPs usually guarantee BOD₅ < 20 mg/L, COD < 60 mg/L, oil & grease < 5 mg/L, and NH₃–N < 2 mg/L (local limits apply). They can go lower for reuse, for example COD < 20 mg/L and TOC < 5 mg/L after RO. A multi‑stage enhanced system in Shanghai (ICBAF + hydrolysis + A/O + MBR + O₃‑AC) processed ~2,500 mg/L influent COD down to ~50 mg/L. It removed >94% of COD, BOD₅, NH₄–N, and P. The first aerated biofilter removed ~83% of BOD₅ (www.nature.com, www.nature.com, www.nature.com).

Sludge and side‑stream management

The API/CPI and DAF steps produce oily sludges and scums. Plants remove the oil and then either send the sludge offsite as hazardous waste or treat it on site. On-site treatment uses thickening and dewatering, and in some cases thermal drying or incineration. Biological trains produce secondary (waste activated) sludge. Co-thickening and centrifuges or filter presses are common. Good pretreatment (API/DAF) cuts sludge volume and disposal cost, which is a major OPEX driver (www.mdpi.com).

Other waste streams need capture and return to the headworks or to solids handling. These are neutralization residuals, filter backwash, and spent GAC regeneration water. Spent GAC can be thermally reactivated or landfilled. Metal hydroxide sludges are settled as solid waste. Consumables and spare parts for these systems sit under standard water/wastewater chemicals and plant ancillaries.

Instrumentation, automation, and safeguards

Modern plants use online pH, DO, redox, turbidity, oil-in-water and nutrient analyzers (ammonia/nitrate) to adjust aeration and dosing in real time. SCADA/PLC controls run the blowers and pumps and handle the interlocks. Autosamplers make composite samples for the lab to check. If an upset happens, such as a crude slug or a caustic leak, the flow goes to emergency equalization or neutralization tanks. Covered tanks and scrubbers deal with odors. CEMS measure air. At the outfall, effluent analyzers and soft sensors (for example UV-Vis surrogates for COD) are becoming more common.

Footprint, energy, and cost

Space matters. For the same flow, a CPI design can have a footprint about 60–75% smaller than an API separator (pt.scribd.com). MBRs use more energy but need smaller clarifiers. Most energy goes to aeration (biology) and pressurization (DAF). One analysis puts API/DAF pretreatment at about 0.09 kWh/m³ against about 0.86 kWh/m³ for MBRs. In that comparison API+DAF uses about 10× less energy and about 1/6 the lifecycle cost of a polishing plant with more treatment steps, and “pretreatment is fifteen times more” cost‑efficient (www.mdpi.com). Where space is tight, a compact settler such as a tube settler can cut basin footprints a further 3–4×.

Industry trends and water reuse

Trends point to deeper membrane integration (MBR, UF), oxidation with stronger oxidants to break down recalcitrants, and movement toward zero‑liquid‑discharge in water‑stressed regions. Refinery water reuse initiatives can cut freshwater intake by 10–40% (values vary by site) according to a Fluence Corp. report cited by sensorex.com. Embedded analytics and smart sensors are being applied to optimize aeration and chemical dosing, including AI‑based NOx control concepts within nitrification strategies, as data becomes another lever on OPEX.

Representative performance snapshots

Wang et al. (Sci. Rep.) reported an ICBAF + hydrolysis + A/O + MBR + O₃‑AC train. It treated ~2,500 mg/L COD influent and removed 94% COD, BOD₅, NH₄–N, and P. The final COD was ~50 mg/L and the TOC ~20 mg/L. The first aerated biofilter alone removed ~83% of BOD₅ (www.nature.com, www.nature.com, www.nature.com). Razavi & Miri (HF‑MBR) observed 82% COD and 89% BOD₅ removal on real refinery wastewater (www.mdpi.com). An API+DAF pretreatment case demonstrated ~90% oil/TSS and ~75% COD removal (Dizayee, 2023, www.mdpi.com, www.mdpi.com).

Reference base and standards

The design and performance figures here come from industry manuals (API 421), peer‑reviewed research on DAF and biological systems (www.researchgate.net and www.nature.com). They also come from cost and energy comparisons of pretreatment and MBR operation (www.mdpi.com and www.mdpi.com), and from Indonesian effluent standards (id.scribd.com). All numerical values and performance benchmarks above are taken directly from these sources.