WhatsApp

Oilfield chemicals

Crude Oil Demulsifier Chemical

Updated

A demulsifier is a surface-active chemical that breaks oil-water emulsions in crude oil. BETAFLOW DM Series is chosen by bottle test on your sample.

Crude Oil Demulsifier Chemical

Discuss the application.

Send the application, operating conditions and the result you expect. Our team will discuss the options with you.

Ask about this product

or use the contact page

What is a crude oil demulsifier?

A demulsifier is a surface-active chemical. It breaks oil-water emulsions in crude oil, so water separates faster, the separator interface becomes sharper and oil BS&W falls to the sales limit. PT Beta Pramesti Asia supplies BETAFLOW DM Series demulsifiers in Indonesia. We select the formulation from bottle tests on your fluid samples, temperature, residence time and injection point. We do not select it from a catalogue dose alone.

BETAFLOW DM 200 Series demulsifier holds a TKDN certificate with a value of 39.78%. See the BETAFLOW TKDN certificates.

BETAFLOW DM 201 is published as a demulsifier for reducing water and sediment in crude oil. BETAFLOW DM 222 breaks emulsions and helps reduce fluid viscosity. The final dose for either product needs optimisation with the actual fluid and operating conditions.

Technically reviewed: 12 November 2026.

Why do oil-water emulsions form?

Emulsions form when water droplets are trapped in oil and coated with a stable film. The stabilisers are natural surfactants, asphaltenes, resins, fine solids, and turbulence from chokes, pumps and pipework. The more stable the film, the more time and heat the separator needs. The risk of water carried into oil or oil carried into water also goes up.

A demulsifier migrates to the oil-water interface, weakens the stabilising film and helps water droplets coalesce and settle. Emulsion stabilisers differ between fields. Therefore a formulation that works in one field may not work in another.

Demulsifier, deoiler, or both?

ProblemLocationProgramme
Water and sediment held in oil (high BS&W)Separator, free water knockout, gun barrel, treaterBETAFLOW DM Series demulsifier (this page)
Oil carried in produced waterSeparator outlet, IAF/DAF, API separatorBETAFLOW DR Series deoiler
Thick emulsion pad at the interfaceSeparators and tanksDemulsifier, often combined with temperature and residence-time adjustment

For other problems in the same facility, such as H2S, wax or scale, see BETAFLOW oilfield chemicals by problem, H2S scavenger and pour point depressant for waxy crude.

What data determine crude oil demulsifier selection?

Demulsifier selection starts with a sample that represents the actual stream, process temperature, emulsion stability, residence time, and the oil and water acceptance limits. A bottle test screens candidates. A field trial then proves dose, injection point, interface quality, re-emulsion tendency, BS&W, separated-water quality, and programme cost.

Buyer inputDecision affectedAcceptance evidence
Sample source, water cut, temperature, API gravity or density, and emulsion historyCandidate chemistry and test conditions representative of the processTraceable sample and documented test conditions
Separator or treater, residence time, temperature, pressure, and mixing patternRequired emulsion break and initial injection locationInterface, separation rate, rag layer, oil in water, and water in oil
Current product and dose, injection point, mixing distance, and production rateTrial-dose range and implementation planChemical consumption, result stability, and response to operating changes
BS&W limit, separated-water quality, re-emulsion risk, and downstream objectiveCandidate acceptance criteriaAgreed test method, result trend, and verification samples

ASTM D4007-22 describes how water and sediment in crude oil are measured in the laboratory by centrifuge. Agree the project product-quality method before the trial. Bottle-test observations do not replace the BS&W test or the other acceptance measurements the facility needs.

How should a comparable demulsifier bottle test be run?

A useful bottle test keeps the sample, temperature, mixing energy, observation time and reading method the same for every candidate. The aim is not just to pick the bottle that looks fastest. The aim is to find candidates that can go to process-equipment testing without losing water quality, interface stability or repeatability.

Only the candidate formulation and its dose vary between bottles. Temperature, mixing energy, observation time and reading method stay the same, so candidates are compared on equal terms. The sample comes from the actual facility stream, and its source, sampling time, water cut and operating conditions are recorded.

  1. Take a representative sample and record its source, time, temperature, water cut, active product and operating conditions at sampling.
  2. Condition every sample portion the same way, then test candidates and doses at a consistent volume and mixing sequence.
  3. Record separation time, water volume, water clarity, interface sharpness, rag layer, sediment and re-emulsion signs at set intervals.
  4. Select several candidates against all criteria, not one observation. Then confirm the BS&W and water-quality methods used by the facility.
  5. Proceed to a controlled field trial with agreed dose limits, injection point, duration, sampling frequency, acceptance criteria and stop conditions.

Every candidate is read in the same observation order:

Bottle-test observationDecision it supports
Separation time and the volume of water droppedWhether the candidate separates fast enough for the separator or treater residence time
Interface sharpness and rag-layer thicknessWhich candidate keeps the interface sharp, or whether temperature and residence time need adjusting
Separated-water clarity and signs of re-emulsionWhich candidate meets the acceptance criteria the facility agrees; re-emulsion signs are judged with the other criteria, not on their own
BS&W by the method the facility agreesWhether the oil meets the acceptance limit; bottle-test observations do not replace the BS&W test
The dose range testedThe starting dose range and dose limits for the controlled field trial

The table maps observations to decisions. What proves dose, injection point, interface clarity and programme cost is the controlled field trial.

BETAFLOW DM 201

Demulsifier - OilField Chemicals

BETAFLOW DM 201 is a chemical used to break emulsions. It helps produce cleaner separated water, establish a clear interface, prevent re-emulsion and reduce basic sediment and water.

Product Benefits

  • Breaks the oil emulsion so water can separate more quickly.
  • Helps produce oil with low BS&W and cleaner separated water.
  • Published as compatible with other chemicals. Confirm actual compatibility for the site programme.

Technical Specifications

Physical Form and OdorDensity, g/ccWater solubilityUsage MethodPackaging
Yellowish to brown liquid, aromatic solvent odour.0.9 ± 0.1InsolubleBETAFLOW DM 201 is injected continuously. Initial points may include wells with heavy emulsions or high production; distance to the separation facility should provide adequate mixing and residence time. Use 5-20 ppm based on produced crude oil as the published starting range, then optimise from field results.200-litre drum.

BETAFLOW DM 222

Viscosity Reducer - OilField Chemicals

BETAFLOW DM 222 is a chemical used to break emulsions and help produce lower viscosity. A viscosity reducer lowers crude-oil resistance to flow, so the fluid is easier to process and move.

Product Benefits

  • Breaks the oil emulsion so water can separate more quickly.
  • Helps produce a fluid with lower viscosity.
  • Published as compatible with other chemicals. Confirm actual compatibility for the site programme.

Technical Specifications

Physical Form and OdorDensity, g/ccWater solubilityUsage MethodPackaging
Yellow to brown liquid, aromatic solvent odour.0.9 ± 0.1InsolubleBETAFLOW DM 222 is injected continuously. Initial points may include wells with heavy emulsions or high production; distance to the separation facility should provide adequate mixing and residence time. Use 10-100 ppm based on produced crude oil as the published starting range, then optimise from field results.200-litre drum.

For a field example of how fluid conditions, injection location, contact time, and operating evidence shape a programme, read the BETAFLOW 9300 crude oil-water separation case study. Review the wider BETAFLOW oilfield chemical portfolio; for injection hardware, compare Watermart industrial dosing pumps by material, capacity, pressure, and control requirement.

Data needed for a demulsifier quotation

Send production rate, water cut, temperature, API gravity or density, BS&W result, separated-water quality, separator or treater type, residence time, current product and dose, injection point, rag-layer or re-emulsion problem, acceptance target, packaging and destination. Use the Beta contact page so the technical team can assess sample needs, bottle testing, a field trial and the quotation basis.

Demulsifier FAQ

What does a demulsifier do in crude oil?

A demulsifier breaks water-in-oil emulsions so water separates faster and cleaner. Therefore the oil BS&W is lower, the separator interface is sharper and the separated water carries less oil.

Where is a demulsifier injected?

Usually this is continuously upstream of the separation facility. For example, at wells with heavy emulsion or high production, with enough distance for mixing and contact time before the separator or treater. The best point is confirmed during the field trial.

Can a demulsifier be used with other chemicals?

BETAFLOW DM Series is published as compatible with other chemicals. However, actual compatibility with the corrosion inhibitor, scale inhibitor, H2S scavenger or antifoam on site still needs to be confirmed by testing before co-injection.

Is the demulsifier with the lowest dose always the most economical?

No. Compare cost at the same production rate and period. Then account for BS&W, water quality, interface stability, re-emulsion, heating demand, packaging, delivery, injection equipment, and test support. A low dose is not economical if the separation or operating-stability target is missed.