Water and waste water chemical
Anionic and Cationic Flocculants BETAGARD
Updated
BETAGARD anionic, cationic and nonionic flocculants from PT Beta Pramesti Asia for clarification, DAF, thickening and sludge dewatering, selected by jar test.
Discuss the application.
Send the application, operating conditions and the result you expect. Our team will discuss the options with you.
What is a flocculant and how do you choose one?
A flocculant is a high-molecular-weight polymer. It bridges fine particles into larger flocs, so they settle faster, float in a DAF unit, or separate in a filter press or screw press. PT Beta Pramesti Asia supplies BETAGARD anionic, cationic and nonionic flocculants in Indonesia. We choose charge, molecular weight and dose from jar tests on your own water or sludge, not from the industry label alone.
BETAGARD anionic flocculant holds a Ministry of Industry TKDN certificate with a value of 45.74%. See the TKDN certificates for water treatment chemicals.
In short: anionic candidates are screened for mineral solids and clarification after a metal-salt coagulant, cationic candidates for organic or biological sludge and dewatering, and nonionic grades are usually included as a comparison in raw-water clarification. A step-by-step guide (in Indonesian) is in the article cara memilih flokulan anionik dan kationik.
A programme can combine coagulants, flocculants, sludge treatment and dosing equipment to suit the water, separation unit and operating target. For independent laboratory testing of water or sludge, use lab.id.
Technically reviewed: 12 November 2026.
Anionic, cationic or nonionic: what is the difference?
| Flocculant type | Polymer charge | Often shortlisted for | Typical dosing point tested | What the test must prove |
|---|---|---|---|---|
| Anionic | Negative | Raw-water clarification, mineral solids, mining slurry and tailings, flocculation after PAC/ACH or iron salts | Clarifier feed, tailings thickener feed, or the flocculation stage after the coagulant | Supernatant clarity, settling rate, floc strength under shear |
| Cationic | Positive | Organic and biological WWTP sludge, DAF with oil and grease, thickening and dewatering | DAF feed, sludge thickener feed, or filter press, screw press and centrifuge feed | Solids capture, filtrate TSS, cake solids, cake release |
| Nonionic | Neutral or very low | Raw-water or process-water clarification, as a comparison with charged candidates | Clarifier feed, as the comparison in the same test | Floc response at the actual pH, salinity and coagulant |
The table is a screening start point, not a fixed rule. Molecular weight and charge density affect bridging, floc strength and ease of make-down. The injection point and the mixing must be tested on the plant so the polymer is distributed evenly without breaking flocs that have already formed; if flocs break after injection, move the injection point or reduce turbulence. Where the process uses a coagulant, the flocculant goes in after the coagulant is mixed; for sludge thickening or dewatering and for some mineral slurries, the flocculant can be used without a coagulant. A jar test should copy that injection point and order, not only the dose; the plant-dosing and common-mistake sections of the flocculant selection article (in Indonesian) cover both. The best candidate meets the water and sludge targets consistently at the lowest programme cost. The general jar-test procedure is described in ASTM D2035, Standard Practice for Coagulation-Flocculation Jar Test of Water.
What drives flocculant cost?
Industrial flocculant cost depends on polymer type, charge, molecular weight and charge density, trial dose, product form (powder or emulsion), purchase volume, logistics, and make-down and dosing requirements. Compare cost per m³ of water or per tonne of dry solids at an equivalent separation result, not price per kilogram alone. That is why this page carries no price per kilogram: a quoted figure only means something once charge and dose are proven in a jar test on your sample. Request a flocculant quotation from the Beta Pramesti Asia team with your water or sludge data.
What should you send for a flocculant quotation?
- Water or sludge source, flow or dry-solids load, and operating hours.
- pH, TSS, COD/BOD, oil and grease, and sludge solids percentage where available.
- Separation unit: clarifier, DAF, thickener, filter press, screw press or centrifuge.
- Current coagulant and flocculant, dose and injection point.
- Previous jar-test results, water and cake targets, pack form and delivery location.
Send the data to the Beta Pramesti Asia team. Then we calculate daily demand and programme cost on the same basis.
Flocculant Applications
- Clarification of raw water and process water.
- Industrial wastewater treatment with high TSS.
- DAF systems for oil, grease and fine suspended solids.
- Sludge thickening and sludge dewatering.
- Mining, slurry, tailings and mineral washing applications.
- Pulp and paper, textile, petrochemical, steel, automotive, and food and beverage industries.
How do you select a flocculant for industrial wastewater?
Start with the separation objective, the solids character and the installed equipment. Laboratory screening should compare ionic charge, dose, dilution, mixing energy, injection sequence and response with the existing coagulant. The strongest candidate is the one that repeatedly meets treated-water and cake targets. It is not simply the product that makes the largest visible floc.
| Process condition | Initial candidate to test | Evidence to compare |
|---|---|---|
| Raw-water or process-water clarification | Anionic, nonionic, or coagulant-aid polymer | Effluent turbidity/TSS, settling rate, supernatant clarity, coagulant demand |
| DAF treating oil, grease, or fine solids | Polymer compatible with the coagulant and DAF recycle stream | Floc strength, float stability, subnatant quality, float-sludge production |
| Thickening or filter press | Flocculant matched to sludge type and charge | Capture rate, filtrate TSS, cycle time, cake solids, cake release |
| Centrifuge or another high-shear zone | Polymer that retains floc under actual shear | Capture rate, centrate TSS, torque, polymer use per dry-solids mass |
| Variable pH or contaminant load | Several charge and molecular-weight ranges | Operating window, pH correction, repeatability across samples |
The US Bureau of Reclamation notes that polymer demand depends on polymer type and purpose. The precise amount is found through jar testing (WaTER technical report). The US EPA dewatering manual also treats jar testing as an initial screen. It calls for evaluation of performance, cost, sludge-volume changes, handling and equipment impacts (US EPA dewatering design manual).
How should a flocculant jar test move to a plant trial?
A jar test should narrow the polymer charge and dose window. It should not be treated as the final plant setting. The plant trial must reproduce the actual dilution water, make-down method, injection order, mixing energy, hydraulic residence time, solids loading and separation equipment. It must also track both water quality and sludge handling.
- Define the untreated baseline. Record feed flow, pH, temperature, turbidity or TSS, sludge solids where relevant, current chemical doses, and the operating condition when the sample was taken.
- Screen one variable at a time. Compare polymer charge or product family first. Then run a dose sweep under the same coagulant, pH, mixing and settling conditions.
- Score the complete separation result. Record supernatant or filtrate quality, settling or flotation behaviour, floc strength, sludge volume, cake release and any downstream effect. Do not score appearance alone.
- Repeat on representative samples. Include normal operation and credible high-load or low-load conditions before choosing the plant-trial candidates.
- Transfer the test basis to the plant. Document stock concentration, aging time, secondary dilution, injection point, pump calibration, and the actual feed solids or flow used to calculate dose.
- Change in controlled steps. Stabilize each condition before comparing results. Keep an agreed fallback setting and confirm that the selected window remains usable across shifts.
Flocculant cost worksheet per dry solids
For dewatering, calculate the flocculant dose as kg of product per ton of dry solids. Do not use ppm on sludge flow alone. This basis makes filter presses, centrifuges, screw presses and DAF easier to compare. Solids loading can change while sludge volume looks unchanged.
| Calculation step | Formula | Example |
|---|---|---|
| Calculate daily dry solids | Sludge flow m³/day × solids percent × 1,000 kg/m³ | 20 m³/day × 2% × 1,000 = 400 kg DS/day |
| Convert the test dose | kg product ÷ ton DS | 2 kg product/day ÷ 0.4 ton DS = 5 kg/ton DS |
| Calculate chemical cost | kg product/day × delivered price/kg | 2 kg/day × delivered price |
| Add supporting costs | Dilution water, coagulant, power, wash water, and sludge handling | Compare total cost, not polymer alone |
| Accept the result | Cake solids, filtrate/centrate TSS, capture rate, and operating stability | Candidate passes only when water quality and cake quality meet target |
Also record the ppm basis when the duty is not dewatering. For clarification or DAF, ppm on water flow helps calculate daily demand. For sludge, kg per ton of dry solids is fairer because feed solids percentage usually changes.
| Dose basis | Formula | Risk if the wrong basis is used |
|---|---|---|
| ppm on water flow | mg/L product × flow m³/day ÷ 1,000 = kg/day | Cost can look low when flow is small but solids load is high |
| kg per ton dry solids | kg product ÷ ton DS | Dose can appear to rise when solids percentage changes, even if kg/day is unchanged |
| kg per ton wet cake | kg product ÷ ton cake | Poor chemical-selection basis because cake moisture changes with the equipment |
| cost per quality target | programme cost ÷ m³ water on spec or ton DS captured | Links price to the result, not consumption alone |
If polymer use rises after start-up, repeat the calculation with actual solids and pump calibration. A higher kg/day can be normal when the solids load rises. A higher kg/ton of dry solids usually points to a change in the sludge, a problem with how the polymer is prepared, or a problem at the injection point.
Why does flocculant performance become unstable?
| Operator symptom | Likely cause | Next check |
|---|---|---|
| Small floc and cloudy supernatant | Wrong polymer charge, underdose, or ineffective upstream coagulation | Repeat the dose sweep; check pH, alkalinity, coagulant, and injection point |
| Floc forms and then breaks | Excessive shear or unsuitable mixing time | Match the test mixing to the actual pipe, pump, DAF, or centrifuge conditions |
| Polymer use rises while results worsen | Overdose, changing feed solids, or poor stock-solution preparation | Check make-down concentration, aging time, pump calibration, and solids loading |
| Slow filter press or sticky cake | Conditioning does not match the sludge and filter cloth | Compare filtrate TSS, cycle time, cake solids, and several polymer charges |
| Results vary between shifts | Inconsistent solution preparation, batch, or operator procedure | Record batch, concentration, preparation time, flow, dose, and result by shift |
What must a polymer make-down and dosing package control?
A polymer package must deliver a repeatable, fully prepared solution at the flow you need without damaging the polymer before it reaches the process. The equipment scope depends on whether the product is powder, emulsion, or liquid. However, the proposal should define preparation, transfer, metering, injection, cleaning and operator checks as one system.
| Package stage | Control to specify | Acceptance evidence |
|---|---|---|
| Product receipt and storage | Product form, package handling, dry storage or temperature limits, spill controls, and safe access | Current product information, storage arrangement, and site HSE review |
| Dilution-water supply | Flow, pressure, water quality, isolation, and a means to confirm the actual dilution ratio | Measured water flow and repeatable batch or continuous concentration |
| Wetting and make-down | Powder wetting or emulsion inversion method, mixing intensity, tank volume, and required preparation time | Uniform solution without fisheyes, undispersed powder, or avoidable high shear |
| Transfer and metering | Compatible wetted materials, duty range, calibration method, turndown, and standby philosophy | Calibrated output across the operating range and stable delivery pressure |
| Injection and process mixing | Injection location, quill or diffuser arrangement, dilution at the point of use, and available mixing energy | Even distribution without breaking the formed floc before separation |
| Cleaning and operating records | Flush route, drain or spill collection, batch identification, concentration, pump setting, and shift result | A repeatable SOP and log that links preparation conditions to treatment performance |
For a quotation, tell us the polymer trial basis and the chemical dosing pump and metering range you need. For dewatering projects, also state the upstream thickening and downstream sludge-treatment conditions. Then we select the package against the complete duty.
Industrial flocculant FAQs
Which supplier provides industrial wastewater flocculants in Indonesia?
PT Beta Pramesti Asia supplies BETAGARD flocculants through beta.co.id for clarification, DAF, thickening and dewatering. Product selection starts with water or sludge data and bench testing. We then confirm the choice on the installed process.
What is the difference between a coagulant and a flocculant?
A coagulant destabilizes the charge on fine particles. A flocculant helps the destabilized particles form larger flocs. Many processes use both. However, injection order and dose need testing for each wastewater stream.
Is an anionic or cationic flocculant better for dewatering?
Neither charge is always better. Sludge type, surface charge, organic content, pH, solids loading, shear and dewatering equipment determine the candidate. Compare tube or jar tests before a plant trial.
What is the difference between anionic and cationic flocculants?
Anionic flocculants carry a negative charge. They are usually used for mineral solids and for clarification after a coagulant. Cationic flocculants carry a positive charge. They are usually screened for organic sludge, biological sludge and dewatering. The final choice is still decided by jar tests and a trial on the actual unit.
What data are needed for a flocculant recommendation?
Please provide the wastewater source, flow, pH, TSS, COD/BOD, oil and grease, sludge solids, current chemicals, injection point, clarifier/DAF/dewatering type, target quality and previous test results. Send the data to the Beta Pramesti team.
Betagard Water Based Polymeric Coagulants and Flocculants
BETAGARD 6400
For Flocculation and Dewatering Treatment
BETAGARD 6400 is a cationic polydiallyl dimethyl ammonium chloride. It works well as a primary coagulant or coagulant aid in water or wastewater purification, pulp and paper industry, textile industry, oil from steel mills, automobile plants, petrochemical plants and others. BETAGARD 6400 reduces the dosage of inorganic coagulants or removes their use. Therefore sludge volumes and treatment costs go down a lot.
CHARACTERISTICS
- Good neutralizing effect against SS electric charge in water.
- Works well on wastewater that contains oil and grease.
- Works well to reduce sludge volume.
- Cationic type.
- Liquid type, easy to handle.
Technical Specifications
| Physical Form | Appearance | pH (0.5% solution) | Main ingredient | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Solid (powder) | White to brass colored powder. | Poly cationic organic coagulant | Poly cationic organic coagulant | Protect face and hands with a mask and rubber gloves to avoid direct contact with Betagard 6400. - In case of direct contact, the affected area should be washed immediately with plenty of clean water. - Store indoors at 0 - 40ºC. - Do not use empty containers for drinking water supply. | Available in plastic container sizes of 15 kgs or PE bags up to 25 kgs. |
Dosage & Usage Instructions:
Dose BETAGARD 6400 at 1 to 50 mg/l with or without dilution. Add it into the coagulation tank or the system pH control tank with a metric pump.
- Inorganic coagulants such as PAC, Alum or ACH work well when used together with BETAGARD 6400.
- After coagulant treatment with BETAGARD 6400, use a suitable high polymer flocculant (Betagard 6100) to form large flocks.
BETAGARD 6100
Anionic Flocculant
BETAGARD 6100 is an anionic polyelectrolyte. It works as a coagulant aid or a sludge conditioning agent in liquid-solids separation. This product is an anionic polymer with a high charge, so it works well as a flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable where the flocks formed are subject to high shear. Stock solutions are usually prepared at a concentration of 0.1 to 0.5%. Because it has a low residual monomer content, BETAGARD 6100 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6100 solution is essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6100 should be stored in a dry place with an ambient temperature of not more than 38o C. Tightly close the drum container after use. | Available in plastic container sizes of 15 kgs or PE bags up to 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6100 for different applications is as follows:
- Flocculant: 0.1 to 2.0 ppm
- Coagulant Aid: 0.05 to 1.0 ppm
- Filtration Aid: 0.01 to 1.0 ppm
- Sludge Dewatering: 0.5 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for stirring. Such stock solutions are stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, further dilute the stock solution with clean water to 0.02% or less before it goes into the process stream. However, this is usually determined by inspection of available facilities. Recommended transfer pumps are gear type or positive displacement piston or diaphragm pumps.
BETAGARD 6100 Series
RO & UF ANTISCALANT and WETTED SURFACE AIR COOLER SCALE INHOBITOR
Betagard 6100 Series is a multifunctional antiscalant and antifoulant for reverse osmosis systems. It works well to control crystallization and particulate fouling on membrane surfaces.
Betagard 6100 will control the scale deposition of CaCO3, CaSO4, BaSO4, and CaF2. Betagard 6100 is formulated to control soluble and insoluble iron and actively disperse particulates. Hydro 600 works well against silica fouling. It is specifically designed for use on Thin Film and CA membranes.
Technical Specifications
| Physical Form | pH | Sp. Gravity at 25 DEG C | Handling and Storage Measures | Packaging |
|---|---|---|---|---|
| Colorless clear colored liquid. | 5.0 - 6.0 | Anionic | Keep out of reach of children. In case of accidental splashing, flush with plenty of water. And for eye contact, must receive medical attention as a safety measure. | Available in plastic container size with a net weight of 200 liters / drum. |
Dosage & Usage Instructions:
Betagard 6100 is an aqueous solution of organic acids. It is corrosive in concentrated form. Therefore you need dosing equipment that resists corrosion. Suitable materials are 316L stainless steel or plastics such as GRP, PVC and PE. Inject it into the feed water downstream of the filtration equipment and cartridge filters. Betagard 6100 mixes with water in all proportions.
It can be applied as a neat product, or as a solution in distillate. A minimum dosage solution strength of 10% w/b is recommended. Betagard 6100 should be dosed continuously and in proportion to the feed water flow, to maintain the recommended dosing rate. The dosage rate you need depends on the feed water quality and the saturation index of the scale forming species present in the concentrated brine. The usual dosage rate range is between 5 and 15 ppm.
BETAGARD 6110
Anionic Flocculant
BETAGARD 6110 is an anionic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. This product is an anionic polymer with a high charge, and it works as an effective flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable for applications where the flocks formed are subject to high shear. Stock solutions are usually prepared at concentrations of 0.1 to 0.5%. Because its residual monomer content is low, BETAGARD 6110 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6110 solution is essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6110 should be stored in a dry place with an ambient temperature of not more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6110 for different applications is as follows:
- Flocculant: 0.1 to 2.0 ppm
- Coagulant Aid: 0.05 to 1.0 ppm
- Filtration Aid: 0.01 to 1.0 ppm
- Sludge Dewatering: 0.5 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for stirring. Such stock solutions are stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, dilute the stock solution further with clean water to 0.02% or less before it goes into the process stream. However, this is usually decided by looking at the facilities you have. We recommend gear type transfer pumps, or positive displacement piston or diaphragm pumps.
BETAGARD 6120
Anionic Flocculant
BETAGARD 6120 is an anionic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. This product is an anionic polymer with a high charge. It works as a good flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable where the flocks formed are subject to high shear. Stock solutions are usually prepared at concentrations of 0.1 to 0.5%. Its residual monomer content is low, so BETAGARD 6120 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6120 solutions are essentially non-corrosive. Recommended construction materials for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6120 should be stored in a dry place with an ambient temperature of no more than 38oC. Close the drum container tightly after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6120 for different applications is as follows:
- Flocculant: 0.1 to 2.0 ppm
- Coagulant Aid: 0.05 to 1.0 ppm
- Filtration Aid: 0.01 to 1.0 ppm
- Sludge Dewatering: 0.5 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for stirring. Such stock solutions are stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, dilute the stock solution further with clean water to 0.02% or less before it goes into the process stream. However, this is usually decided by looking at the facilities you have. We recommend gear type transfer pumps, or positive displacement piston or diaphragm pumps.
BETAGARD 6130
Anionic Flocculant
BETAGARD 6130 is an anionic polyelectrolyte. It works as a coagulant aid or a sludge conditioning agent in liquid-solids separation. This product is an anionic polymer with a high charge. It works as a flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable where the flocks formed are subject to high shear. Stock solutions are usually prepared at concentrations of 0.1 to 0.5%. Because it has a low residual monomer content, BETAGARD 6130 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6130 solutions are essentially non-corrosive. Recommended construction materials for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6130 should be stored in a dry place with an ambient temperature of no more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6130 for different applications is as follows:
- Flocculant: 0.1 to 2.0 ppm
- Coagulant Aid: 0.05 to 1.0 ppm
- Filtration Aid: 0.01 to 1.0 ppm
- Sludge Dewatering: 0.5 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for stirring. Such stock solutions are stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, dilute the stock solution further with clean water to 0.02% or less before it goes into the process stream. However, this is usually determined by inspection of the available facilities. The recommended transfer pumps are gear type or positive displacement piston or diaphragm pumps.
BETAGARD 6140
Anionic Flocculant
BETAGARD 6140 is an anionic polyelectrolyte. It works as a coagulant aid or a sludge conditioning agent in liquid-solids separation. This product is an anionic polymer with a high charge. It works as a flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable where the flocks formed are subject to high shear. The stock is usually prepared at a concentration of 0.1 to 0.5%. Because it has a low residual monomer content, BETAGARD 6140 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6140 solutions are essentially non-corrosive. Recommended construction materials for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6140 should be stored in a dry place with an ambient temperature of not more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6140 for different applications is as follows:
- Flocculant: 0.1 to 2.0 ppm
- Coagulant Aid: 0.05 to 1.0 ppm
- Filtration Aid: 0.01 to 1.0 ppm
- Sludge Dewatering: 0.5 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory tube test. The stock is usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for stirring. This stock stays stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, dilute the stock further with clean water to 0.02% or less before it goes into the process stream. However, this is usually determined by inspection of the available facilities. The recommended transfer pumps are gear type or positive displacement piston or diaphragm pumps.
BETAGARD 6150
Anionic Flocculant
BETAGARD 6150 is an anionic polyelectrolyte. It serves as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. This product is an anionic polymer with a high charge. It works as a flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable for applications where the flocks formed are subject to high shear. The stock is usually prepared at a concentration of 0.1 to 0.5%. Because it has a low residual monomer content, BETAGARD 6150 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6150 solutions are essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6150 should be stored in a dry place with an ambient temperature of no more than 38oC. Close the drum container tightly after use. | Available in plastic drum size 15 kgs or PE bag - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6150 for different applications is as follows:
- Flocculant: 0.2 to 2.0 ppm
- Coagulant Aid: 0.1 to 1.0 ppm
- Filtration Aid: 0.02 to 1.0 ppm
- Sludge Dewatering: 0.5 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for stirring. These stock solutions are stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, dilute the stock solution further with clean water to 0.02% or less before you add it to the process stream. However, this is usually determined by inspection of the available facilities. The recommended transfer pumps are gear type or positive displacement piston or diaphragm pumps.
BETAGARD 6160
Anionic Flocculant
BETAGARD 6160 is an anionic polyelectrolyte. It works as a coagulant aid or a sludge conditioning agent in liquid-solids separation. This product is an anionic polymer with a high charge, and it works as an effective flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable where the flocks formed face high shear. Stock solutions are usually prepared at a concentration of 0.1 to 0.5%. Its residual monomer content is low, so BETAGARD 6160 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6160 solutions are essentially non-corrosive. Recommended construction materials for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6160 should be stored in a dry place with an ambient temperature of no more than 38oC. Close the drum container tightly after use. | Available in plastic drum size 15 kgs or PE bag - 25 kgs. |
Dosage & Usage Instructions:
We recommend the following dosage of BETAGARD 6160 for different applications:
- Flocculant: 0.2 to 2.0 ppm
- Coagulant Aid: 0.1 to 1.0 ppm
- Filtration Aid: 0.02 to 1.0 ppm
- Sludge Dewatering: 1.0 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high-speed, high-shear mechanical mixers for stirring. These stock solutions are stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, dilute the stock solution further with clean water to 0.02% or less before you add it to the process stream. However, this is usually determined by inspection of the available facilities. The recommended transfer pumps are gear type or positive displacement piston or diaphragm pumps.
BETAGARD 6170
Anionic Flocculant
BETAGARD 6170 is an anionic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation. This product is an anionic polymer with a high charge, so it works as a flocculant in many liquid/solids separation systems, including clarification, thickening and dewatering. This product is suitable where the flocks formed are subject to high shear. Stock solutions are usually prepared at a concentration of 0.1 to 0.5%. Its residual monomer content is low, so BETAGARD 6170 can be used in drinking water treatment up to a maximum concentration of 1.0 mg/l, as approved by the Indonesian Ministry of Health.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Anionic | Very High | BETAGARD 6170 solution is essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6170 should be stored in a dry place with an ambient temperature of no more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 15 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6170 for different applications is as follows:
- Flocculant: 0.2 to 2.0 ppm
- Coagulant Aid: 0.1 to 1.0 ppm
- Filtration Aid: 0.02 to 1.0 ppm
- Sludge Dewatering: 1.0 to 4.0 kg per ton of dry solids
The actual dosage should be determined in a laboratory test tube. Stock solutions are usually prepared at a concentration of 0.1 to 0.5%. Do not use high-speed, high-shift mechanical mixers for stirring. Such stock solutions are stable for at least 3 days. Refer to the polymer mixing procedure bulletin. For best performance, further dilute the stock solution with clean water to 0.02% or less before it goes into the process stream. However, this is usually determined by inspection of available facilities. Recommended transfer pumps are gear type or positive displacement piston or diaphragm pumps.
BETAGARD 6200
Cationic Flocculant
BETAGARD 6200 is a cationic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation. This product is used primarily for wastewater purification, and also for thickening and dewatering municipal and industrial sewage sludge (centrifuges, belt filter presses, chamber filter presses). This product is particularly suitable where the formed flocks are subjected to high shear.
Stock solutions are usually prepared at a concentration of 0.1 to 0.5%.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Cationic | Very High | BETAGARD 6200 solution is essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6200 should be stored in a dry place with an ambient temperature of not more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 15 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6200 for different applications is as follows:
- Clarification of secondary effluent: 1 - 5 ppm.
- Flocculation, thickening and dewatering of primary and secondary sludge from municipal sewage and from several industries: 0.5 - 4.0 kg per ton of dry solids.
- Centrifugal operation: 1.5 - 5.0 kg per ton of dry solids.
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for agitating. This stock solution is stable for at least two days without significant changes in its charge density that could affect its performance results. To keep the solution stable, use water with a temperature lower than 40oCfor dissolution. Also control the pH of the solution within the range of 5.0 to 6.5. For best performance, dilute the stock solution further with clean water to 0.02% to 0.03% or less before feeding it to the process stream. Dilution can be done using in-line dilution or by using a dilution tank. However, this is usually determined by inspection of the facilities available. The recommended transfer pumps are gear type piston pumps or positive displacement piston pumps.
BETAGARD 6210
Cationic Flocculant
BETAGARD 6210 is a cationic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. This product is used mainly for wastewater purification, and for thickening and dewatering municipal and industrial sewage sludge (centrifuges, belt filter presses, chamber filter presses). This product is particularly suitable for applications where the formed flocks are subjected to high shear.
Stock solutions are usually prepared at a concentration of 0.1 to 0.5%.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Cationic | Very High | BETAGARD 6210 solution is essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6210 should be stored in a dry place with ambient temperature not more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6210 for different applications is as follows:
- Clarification of secondary effluent: 1 to 5 ppm.
- Flocculation, thickening and dewatering of primary and secondary sludge from municipal sewage and from several industries: 0.5 to 4.0 kg per ton of dry solids.
- Centrifugal operation: 1.5 to 5.0 kg per ton of dry solids.
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for agitating. This stock solution is stable for at least two days. Its charge density does not change much in that time, so its performance results stay the same. To keep the solution stable, use water with a temperature lower than 40oCfor dissolution. The pH of the solution should be kept in the range of 5.0 to 6.5. For best performance, dilute the stock solution further with clean water to 0.02% to 0.03% or less before feeding it to the process stream. Dilution can be done with in-line dilution or with a dilution tank. However, this is usually decided by looking at the facilities available. The recommended transfer pumps are gear type piston pumps or positive displacement piston pumps.
BETAGARD 6220
Cationic Flocculant
BETAGARD 6220 is a cationic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. This product is used primarily for wastewater purification, as well as for thickening and dewatering municipal and industrial sewage sludge (centrifuges, belt filter presses, chamber filter presses). This product is particularly suitable for applications where the formed flocks are subjected to high shear.
Stock solutions are usually prepared at a concentration of 0.1 to 0.5%.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Cationic | Very High | BETAGARD 6220 solution is essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6220 should be stored in a dry place with an ambient temperature of not more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6220 for different applications is as follows:
- Clarification of secondary effluent: 1 to 5 ppm.
- Flocculation, thickening, and dewatering of primary and secondary sludge of municipal sewage and of several industries: 0.5 to 4.0 kg per ton of dry solids.
- Centrifugal operation: 1.5 to 5.0 kg per ton of dry solids.
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for agitating. This stock solution is stable for at least two days without significant changes in its charge density that could affect its performance results. To make sure the solution stays stable, use water with a temperature lower than 40oCfor dissolution. The pH of the solution should be kept in the range of 5.0 to 6.5. For best performance, dilute the stock solution further with clean water to 0.02% to 0.03% or less before feeding it to the process stream. Dilution can be done using in-line dilution or by using a dilution tank. However, this is usually determined by inspection of the facilities available. The recommended transfer pumps are gear type piston pumps or positive displacement piston pumps.
BETAGARD 6230
Cationic Flocculant
BETAGARD 6230 is a cationic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. This product is used primarily for wastewater purification, as well as for thickening and dewatering municipal and industrial sewage sludge (centrifuges, belt filter presses, chamber filter presses). This product is particularly suitable for applications where the formed flocks are subjected to high shear.
Stock solutions are usually prepared at a concentration of 0.1 to 0.5%.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Cationic | Very High | BETAGARD 6230 solution is essentially non-corrosive. Recommended construction materials for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6230 should be stored in a dry place with an ambient temperature of not more than 38oC. Close the drum container tightly after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6230 for different applications is as follows:
- Clarification of secondary effluent: 1 to 5 ppm.
- Flocculation, thickening, and dewatering of primary and secondary sludge of municipal sewage and of several industries: 0.5 to 4.0 kg per ton of dry solids.
- Centrifugal operation: 1.5 to 5.0 kg per ton of dry solids.
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for agitating. This stock solution is stable for at least two days without significant changes in its charge density that could affect its performance results. To keep the solution stable, use water with a temperature lower than 40oCfor dissolution. The pH of the solution should be controlled within the range of 5.0 to 6.5. For best performance, dilute the stock solution further with clean water to 0.02% to 0.03% or less before feeding it to the process stream. Dilution can be done using in-line dilution or by using a dilution tank. However, this is usually determined by inspection of the facilities available. The recommended transfer pumps are gear type piston pumps or positive displacement piston pumps.
BETAGARD 6240
Cationic Flocculant
BETAGARD 6240 is a cationic polyelectrolyte. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. This product is used primarily for wastewater purification, as well as for thickening and dewatering municipal and industrial sewage sludge (centrifuges, belt filter presses, chamber filter presses). This product is particularly suitable for applications where the formed flocks are subjected to high shear.
Stock solutions are usually prepared at a concentration of 0.1 to 0.5%.
Technical Specifications
| Physical Form | Bulk Density, gr/ml | Ionic Charge | Molecular Weight | Handling and Storage Measures | Packaging |
|---|---|---|---|---|---|
| Off white colored powder. | 0.65 - 0.90 | Cationic | Very High | BETAGARD 6240 solution is essentially non-corrosive. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Spilled polymer is very slippery. Spilled polymer should be scooped up and wiped off before rinsing with water. BETAGARD 6240 should be stored in a dry place with an ambient temperature of not more than 38oC. Tightly close the drum container after use. | Available in fiber drum or PE bag size - 25 kgs. |
Dosage & Usage Instructions:
The recommended dosage of BETAGARD 6240 for different applications is as follows:
- Clarification of secondary effluent: 1 to 5 ppm.
- Flocculation, thickening, and dewatering of primary and secondary sludge of municipal sewage and of several industries: 0.5 to 4.0 kg per ton of dry solids.
- Centrifugal operation: 1.5 to 5.0 kg per ton of dry solids.
The actual dosage should be determined in a laboratory tube test. Stock solutions are usually made to a concentration of 0.1 to 0.5%. Do not use high speed, high shear mechanical mixers for agitating. This stock solution is stable for at least two days without significant changes in its charge density that could affect its performance results. To keep the solution stable, use water with a temperature lower than 40oCfor dissolution. The pH of the solution should be controlled within the range of 5.0 to 6.5. For best performance, dilute the stock solution further with clean water to 0.02% to 0.03% or less before feeding it to the process stream. Dilution can be done using in-line dilution or by using a dilution tank. However, this is usually determined by inspection of the facilities available. The recommended transfer pumps are gear type piston pumps or positive displacement piston pumps.
Contact Us
Flocculant Make-Down and Dosing Checklist
Flocculant performance usually fails because the stock solution has not matured, the dilution water is unsuitable or the injection point applies too much shear. The selected grade is usually not the cause. Use particle charge, separation duty and sludge-solids data to screen anionic or cationic candidates. The final dosage still needs a tube test and a field trial.
| Check | Evidence required | Risk if missed |
|---|---|---|
| Stock solution | Product make-down concentration, hydration time and mixer conditions | Incomplete dissolution produces weak floc and higher consumption. |
| Dilution water | Water source, cleanliness and dilution rate before injection | Performance shifts when solution is too concentrated or contaminated. |
| Injection point | Order relative to coagulant, contact time and pump type | Shear can break floc or chemicals can meet in the wrong sequence. |
| Downstream unit | Clarifier, DAF, filter, thickener or dewatering unit receiving the floc | The same grade can perform differently when the separation mechanism changes. |
| Dose verification | Effluent turbidity/TSS, sludge volume and dry solids, and chemical consumption | Avoid selecting on visual clarity alone or on a single grab sample. |
For a combined chemistry and transfer review, contact PT Beta Pramesti Asia with test results, flow and sludge data. A dosing pump and a coagulation-flocculation programme should be selected together. Then a correctly prepared flocculant is not damaged before it reaches the separation unit.
Want to know more about BETAGARD Anionic and Cationic Oil Based Polymeric Flocculants? Contact us now for more information or for technical consultation about the application of this product in your water treatment system.
Calculating Stock Solution and Pump Flow
Base the pump setting on the mass of active or commercial product that actually enters the process, not on a percentage with no stated basis. For a dry-powder solution expressed as mass per volume, a 0.2% solution contains 2 g/L.
| Worked calculation | Result | Check before use |
|---|---|---|
| 1,000 L of 0.2% stock solution from dry polymer | 2 kg product made up to a final volume of 1,000 L | Follow the product sheet for wetting order, hydration time, temperature and concentration limits. |
| Product demand of 0.6 kg/h using 0.2% stock | 300 L/h stock-solution flow | Confirm that the pump is stable at the actual flow and discharge pressure. |
| Diluting 300 L/h stock to a 0.05% point-of-use solution | 1,200 L/h total flow; add 900 L/h water | Verify dilution-water flow and avoid adding shear after floc has formed. |
These examples show a mass balance only. For density, active content of liquid and emulsion products, inversion method and make-down limits, follow the product document that applies. Calibrate the chemical dosing pump with a safe measured-volume method. Then check daily consumption against the water volume or dry-solids tonnage actually treated.
Each batch record should show the product and lot, product mass, final volume, target concentration, preparation start, ready-for-use time, operator, tank and solution inspection. That record turns weak floc or high consumption into a testable diagnosis. Without it, a dose change cannot be explained.