Water and waste water chemical
Coagulant Water Treatment Indonesia
Updated
PAC and ACH coagulants from our own plant (BPJPH halal, NSF/ANSI/CAN 60; SNI liquid PAC) and POLYDADMAC for WTPs and WWTPs, chosen by jar test.
Discuss the application.
Send the application, operating conditions and the result you expect. Our team will discuss the options with you.
What is a coagulant in water treatment?
A coagulant is a chemical that neutralises the charge on fine particles, colloids and colour in water. The particles then join into flocs that can be settled, floated by DAF, or filtered. The most widely used coagulants are PAC and ACH (aluminium-based) and the organic coagulant POLYDADMAC. PT Beta Pramesti Asia makes PAC and ACH in its own plant and supplies BETAGARD coagulants for water and wastewater treatment plants in Indonesia.
Updated: 20 November 2026.
Our plant has a capacity of 40,000 tonnes of PAC 12 per year and 12,000 tonnes of ACH per year. BETAGARD liquid PAC is certified to SNI 3822:2018. Our PAC and ACH are listed on the BPJPH halal certificate and the NSF/ANSI/CAN 60 listing (see the certifications page). Plant, supply-form and quality-document details are on the PAC and ACH plant page.
| Coagulant type | Chemistry | Active-content class | When it is chosen |
|---|---|---|---|
| Liquid PAC | Poly aluminium chloride, medium basicity | About 8–17% Al₂O₃ | Clarification of raw water, process water and wastewater with continuous dosing |
| Powder PAC | Poly aluminium chloride | About 28–30% Al₂O₃ | Compact storage with on-site dissolving |
| ACH | Aluminium chlorohydrate, high basicity | 22–24% Al₂O₃ | Low-alkalinity water or where the pH change must stay small |
| POLYDADMAC | Cationic organic polymer | No Al₂O₃ | Coagulant aid or primary coagulant for DAF, filtration and dewatering |
A coagulation programme is usually paired with flocculants, sludge treatment, or broader water and waste water chemicals. Chemical name and active content help screen candidates. However, the dose is still set by a jar test on an actual sample and confirmed in a plant trial. Compare the types on the PAC and ACH pages and in the PAC versus alum comparison.
Before selecting a product, use the chemical wastewater treatment method guide to map contaminants, process sequence, jar-test gates, residuals, and sludge consequences.
PAC, ACH, or POLYDADMAC coagulants: when are they used?
| Operator question | Field condition | Relevant product or program | Data to check |
|---|---|---|---|
| Which supplier provides coagulants and flocculants for industrial wastewater in Indonesia? | TSS, turbidity, color, or oil is not dropping in a clarifier, DAF, or sedimentation process | The Betagard series on this page and flocculants | pH, alkalinity, turbidity, TSS, color, oil and grease, flow rate, and jar-test results |
| When should PAC be selected for raw water or process water? | An inorganic coagulant is needed for surface water, process water, or wastewater clarification | BETAGARD 4008, 4010, 4012, 4017, 4031, 4033, and PAC | Initial pH, PAC dosage, aluminum residual, turbidity before and after treatment, and floc formation |
| When should ACH or aluminum chlorohydrate coagulants be considered? | The process needs a high-Al2O3 coagulant or coagulant aid for liquid-solid separation | BETAGARD 4040, 4040 Series, 4041, 4044, and 4045 | Jar-test result, operating pH, sludge character, color, organic matter, and material compatibility |
| When is an organic POLYDADMAC coagulant used? | The system needs a primary coagulant or coagulant aid for clarification, DAF, filtration, centrifugation, or dewatering | BETAGARD 4050 and 4050 Series | TSS, color, oil and grease, separation unit type, sludge dry solids, and injection point |
For chemical injection equipment, see Beta dosing pumps or Watermart dosing pumps for water treatment. If the plant’s baseline coagulant is alum, use the PAC-versus-alum comparison to align test basis, pH, alkalinity, sludge, and programme cost before requesting a quotation.
RFQ data that determines a wastewater coagulant trial
A wastewater coagulant RFQ should define influent character, the separation unit, current chemistry, effluent targets, and sludge-handling limits. Those facts determine the candidates and test design. If the requirement is already specific to polyaluminium chloride, use the PAC coagulant supplier page to compare grades, packaging, and supply-price basis.
| RFQ data | Details to record | Decision affected |
|---|---|---|
| Wastewater profile | Waste source, continuous or batch operation, average/peak flow, pH, alkalinity, TSS, colour, oil and grease | Sample type, test range, pH correction, and chemical candidates |
| Current chemical programme | Product name, actual dose, solution concentration, injection order and point | Comparison baseline and whether a chemical should be replaced or paired |
| Separation unit | Clarifier, sedimentation, DAF, filtration, centrifugation, or dewatering | Required floc-formation speed, floc strength, and separation time |
| Dosing system | Tank capacity and material, mixer, pump, calibration result, and interlocks | Ability to handle the product form and maintain the true dose |
| Target and sludge route | Effluent target, sludge volume, withdrawal frequency, and dewatering response | Trial limits that avoid transferring the problem to sludge handling |
| Supply requirement | Monthly consumption, packaging, site location, unloading access, and safety stock | Quotation basis and supply schedule after a candidate passes the trial |
Coagulant jar-test acceptance table
A coagulant jar test is useful for a quotation only if you compare candidates on the same sample, pH, mixing time, separation time and quality target. Record the result as programme cost per m³ or per kg of TSS removed. Do not record it as mg/L of product alone.
| Test evidence | How to normalize it | Decision boundary |
|---|---|---|
| Product dose | mg/L as supplied, solution concentration, and active content where available | Prevents liquid PAC, PAC powder, ACH, and POLYDADMAC from being compared on different bases |
| Water condition | Initial/final pH, alkalinity, TSS, colour, oil and grease, and temperature | Shows whether performance comes from coagulation or only pH correction |
| Floc formation | Floc speed, size, strength, and shear response | Selects a product that survives the actual mixer, pump, DAF, or clarifier |
| Treated-water quality | Turbidity, TSS, colour, oil and grease, COD where relevant, and metal residual | Connects the bench test to effluent or process-water targets |
| Sludge impact | Sludge volume, settleability, cake/filtrate if tested, and flocculant need | Avoids a choice that transfers cost to dewatering |
| Programme cost | Product, pH correction, polymer, sludge handling, and supply frequency | Defines the real cost after all supporting chemicals are counted |
To compare liquid PAC, PAC powder, ACH, and POLYDADMAC fairly, make two dose numbers: the as-supplied product dose and the active or Al2O3 basis where data are available. This matters because a product with a higher price per kg can still cost less when the active content, pH correction or sludge impact is better.
| Dose normalization | Practical formula | When to use it |
|---|---|---|
| As-supplied product | mg/L of product added to the sample | Daily consumption, stock, and delivered-price basis |
| Active or Al2O3 basis | mg/L product × active percentage | Comparing PAC/ACH grades without treating dilution water as active material |
| Cost per m³ | dose mg/L × flow m³/day × price/kg ÷ 1,000 | Estimating chemical cost at the same flow |
| Complete programme cost | coagulant + pH adjustment + flocculant + sludge handling | Selecting the programme with the true lower operating cost |
If two candidates reach the same effluent quality, choose the one that stays stable on normal and peak-load samples. Do not choose the one that looks clearest in a single beaker. For DAF or sludge applications, keep testing with sludge treatment so underflow, cake and filtrate are included.
How should a jar-test result move to a plant trial?
A jar-test result should move to a plant trial only when the dose, pH, injection sequence and quality targets are written down. PT Beta Pramesti Asia usually asks for an operating baseline before the trial. Then a coagulant change is not confused with a change in flow, pH, TSS load, oil, or clarifier and DAF condition.
| Requirement before trial | Minimum evidence | Why it matters |
|---|---|---|
| Sample represents operation | Sampling time, flow, pH, TSS, colour, oil and grease, and production condition | Avoids choosing a product from a sample that is too light or too severe |
| Dose can be injected | Solution concentration, pump capacity, injection point, and mixing time | Confirms the test dose is actually delivered in the plant |
| Quality target is clear | Turbidity, TSS, colour, FOG, COD where relevant, and sludge limits | Defines when the trial is accepted or stopped |
| Sludge impact is counted | Sludge volume, settleability, polymer demand, cake, and filtrate | Prevents cost from moving from treated water to dewatering |
Betagard Coagulant Series
BETAGARD 4008
Polyaluminum Chloride
BETAGARD 4008 is a yellow to amber colored liquid. It works as a coagulant aid or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4008 is used in water & wastewater treatment to reduce suspended solids (tubidity), color and other contaminants such as natural organic matter from surface water, colloidal particles, salts and clays. These particles are stabilized by surface electrostatic charges that prevent them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Basicity | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|---|
| Clear to yellowish liquid. | Min 8% | Min 1.16 | 3,0 - 5.0 | Min. 35% | The actual dosage for BETAGARD 4008 should be determined in a tube test in the laboratory. Please ask your technical assistant for tube tests or plant trials. | BETAGARD 4008 is a mildly acidic, stable under ordinary conditions substance. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics and other more resistant materials. Galvanized equipment should not be used. Tightly seal drum containers after use. See MSDS for additional information. | Available in 25, 30 KG per bucket, 220 KG per plastic drum or 1200 KG per tote. |
BETAGARD 4010
Polyaluminum Chloride 10%
BETAGARD 4010 is a clear to yellowish liquid. It works as a coagulant or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4010 is used in water & wastewater treatment to reduce suspended solids (tubidity), color and other contaminants such as natural organic matter from surface water, colloidal particles, salts and clays. These particles are stabilized by surface electrostatic charges that prevent them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Basicity | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|---|
| Clear to yellowish liquid. | Min 10% | Min 1.19 | 3,0 - 5.0 | Min. 35% | The actual dosage for BETAGARD 4010 should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4010 is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly close drum containers after use. Refer to MSDS for additional information. | Available in 25, 35 KG per bucket, 240 KG per plastic drum or 1200 KG per tote. |
BETAGARD 4012
POLYALUMUNIUM CHLORIDE 12%
BETAGARD 4012 is a yellow to dark amber colored liquid. It works as a coagulant aid or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4012 is used in water & wastewater treatment to reduce suspended solids (tubidity), color and other contaminants such as natural organic matter from surface water, colloidal particles, salts and clays. These particles are stabilized by a surface electrostatic charge that prevents them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Basicity | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|---|
| Clear to yellowish liquid. | Min 12% | Min 1.24 | 3,0 - 5.0 | Min. 35% | The actual dosage for BETAGARD 4012 should be determined in a tube test in the laboratory. Please ask your technical assistant for tube tests or plant trials. | BETAGARD 4012 is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly close drum containers after use. See MSDS for additional information | Available in 25, 35 KG per bucket, 240 KG per plastic drum or 1200 KG per tote. |
BETAGARD 4012 Series
RAW WATER CLARIFIER COAGULANT AID POLYALUMUNIUM CHLORIDE (PAC)
BETAGARD 4012 Series is a yellow to dark amber liquid. It works as a coagulant or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4012 is used in water and wastewater treatment to reduce suspended solids (tubidity), color and other contaminants. These include natural organic matter from surface water, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Basicity | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|---|
| Yellowish to brown liquid. | Min 12% | 1.19 - 1.40 | 3,5 - 5.0 | Min. 45% | The actual dosage for BETAGARD 4012 Series should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4012 Series is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly seal drum containers after use. Refer to MSDS for additional information. | Available in 200 Liter or 1000 Liter sizes. |
BETAGARD 4017
POLYALUMUNIUM CHLORIDE 17%
BETAGARD 4017 is a clear to yellowish liquid. It works as an auxiliary coagulant or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4017 is used in water and wastewater treatment to reduce suspended solids (tubidity), color and other contaminants. These include natural organic matter from surface water, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Basicity | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|---|
| Clear to yellowish liquid. | Min 17% | Min 1.30 | 3,0 - 5.0 | Min. 35% | The actual dosage for BETAGARD 4017 should be determined in a tube test in the laboratory. Please ask your technical assistant for tube tests or plant trials. | BETAGARD 4017 is a mildly acidic, stable under ordinary conditions substance. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics and other more resistant materials. Galvanized equipment should not be used. Tightly seal drum containers after use. See SDS for additional information. | Available in 25, 35 KG per bucket, 240 KG per plastic drum or 1300 KG per tote. |
BETAGARD 4031
PAC POWDER
BETAGARD 4031 is a white powder. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. BETAGARD 4031 is used in water and wastewater treatment to reduce suspended solids (tubidity), color and other contaminants. These include natural organic matter from surface water, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | pH 1% | Insoluble | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|
| White powder. | Min 30% | 3,5 - 5.0 | Max. 0.05% | The actual dosage for BETAGARD 4031 should be determined in a tube test in the laboratory. Please ask your technical assistant for tube tests or plant trials. | BETAGARD 4031 is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly close drum containers after use. See SDS for additional information. | Available in 25 Kg/bag. |
BETAGARD 4033
PAC POWDER
BETAGARD 4033 is a yellow powder. It works as a coagulant adjuvant or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4033 is used in water and wastewater treatment to reduce suspended solids (tubidity), color and other contaminants. These include natural organic matter from surface water, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | pH 1% | Insoluble | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|
| Yellow colored powder. | Min 28% | 3,5 - 5.0 | Max. 1,5% | The actual dosage for BETAGARD 4033 should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4033 is moderately acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly close drum containers after use. See SDS for additional information. | Available in 25 Kg/bag. |
BETAGARD 4040
ALUMINUM CHLOROHYDRATE (ACH)
BETAGARD 4040 is a clear colorless liquid with a high Al2O3 content. It works as a coagulant or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4040 is used in water and wastewater treatment to reduce suspended solids (tubidity), color and other contaminants. These include natural organic matter from surface water, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|
| Clear to slightly hazy colored liquid. | 22 - 24% | 1.33 - 1.38 @ 20°C | 3,0 - 5.0 | Actual dosage should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4040 is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly close drum containers after use. Refer to MSDS for additional information. | Available in 30 Kg, 270 Kg or 1350 Kg plastic container sizes. |
BETAGARD 4040 Series
RAW WATER COAGULANT AID ALUMINUM CHLOROHYDRATE (ACH)
BETAGARD 4040 Series is a clear colorless liquid with a high Al2O3 content. It works as a coagulant aid or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4040 is used in water and wastewater treatment to reduce suspended solids (tubidity), color and other contaminants from surface water. These include natural organic matter, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|
| Clear to slightly hazy colored liquid. | 22 - 24% | 1.30 - 1.38 @ 20°C | 3,0 - 5.0 | Actual dosage should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4040 Series is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly seal drum containers after use. See MSDS for additional information. | Available in plastic container sizes of 200 Liters/drum or 1000 Liters/IBC tank. |
BETAGARD 4041
ALUMINUM CHLOROHYDRATE+
BETAGARD 4041 is a high performance coagulant based on aluminum chlorohydrate blended with organic polymers. It is formulated for the treatment of industrial effluents, including wastewater from food and dairy processing, and from the oil, textile and chemical industries. BETAGARD 4041 is a clear yellow to amber colored liquid with high Al2O3 content. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. BETAGARD 4041 is used in water & wastewater treatment to reduce suspended solids (tubidity), color and other contaminants from surface water. These include natural organic matter, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|
| Clear to slightly hazy colored liquid. | Min. 23% | 1.32 - 1.38 @ 20°C | 3,5 - 5.0 | Actual dosage should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4041 is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly seal drum containers after use. See MSDS for additional information. | Available in 30, 300 and 1300 kgs plastic container sizes. |
BETAGARD 4044
ALUMINUM CHLOROHYDRATE+
BETAGARD 4044 is a high performance coagulant based on aluminum chlorohydrate blended with organic polymers. It is formulated for the treatment of industrial effluents, including effluents from food and dairy processing, and from the oil, textile and chemical industries. BETAGARD 4044 is a clear colorless liquid with a high Al2O3 content. It works as a coagulant aid or sludge conditioning agent in liquid-solids separation processes. BETAGARD 4044 is used in water & wastewater treatment to reduce suspended solids (tubidity), color and other contaminants from surface water. These include natural organic matter, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 10% | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|
| Yellow to amber colored liquid. | 15% | 1.20 - 1.30 @ 20°C | 3,0 - 5.0 | The actual dosage should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4044 is mildly acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly close drum containers after use. See MSDS for additional information. | Available in plastic container sizes with net weights of 30, 300, and 1300 kg. |
BETAGARD 4045
ALUMINUM CHLOROHYDRATE (ACH)
BETAGARD 4045 is a clear colorless liquid with a high Al2O3 content. It works as a coagulant or sludge conditioning agent in the liquid-solids separation process. BETAGARD 4045 is used in water and wastewater treatment to reduce suspended solids (tubidity), color and other contaminants from surface water. These include natural organic matter, colloidal particles, salts and clays. Surface electrostatic charges stabilize these particles and stop them from coalescing.
Technical Specifications
| Physical Form | %Al203 | Specific gravity | pH 1% | Dosage & Usage Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|---|
| Clear to slightly hazy colored liquid. | 22 - 24% | 1.33 - 1.38 @ 20°C | 3,5 - 5.0 | Actual dosage should be determined in a tube test in the laboratory. Please ask your technical assistant for jar tests or plant trials. | BETAGARD 4045 is moderately acidic, stable under ordinary conditions. Recommended materials of construction for solution handling include black iron, mild steel, fiber glass, plastics, and other more resistant materials. Galvanized equipment should not be used. Tightly close drum containers after use. Refer to MSDS for additional information. | Available in 30 kg, 270 kg or 1350 kg plastic container sizes. |
BETAGARD 4050
ORGANIC COAGULANT
BETAGARD 4050 is a concentrated liquid of low molecular weight. It is a cationic polydiallyl dimethyl ammonium chloride, or POLYDADMAC. It works well as a primary coagulant or as a coagulant aid in water or wastewater clarification. It is chlorine-resistant and works over a wide pH range. It can replace inorganic primary coagulants such as alum and ferric salts, or be used together with them. The maximum recommended concentration of BETAGARD 4050 for potable water treatment is 20 ppm. BETAGARD 4050 is also recommended for other liquid-solids separation processes, such as:
- Dewatering of many industrial and municipal sludges
- Removal of suspended solids from wastewater
- Gravity settling
- Filtration
- Centrifugation
- Air flotation
- Oil and water separation
- Color Removal
Technical Specifications
| Physical Form | Specific gravity | Ionic Charge | Handling Precautions | Packaging |
|---|---|---|---|---|
| Colorless to yellow clear liquid. | 1.33 - 1.38 @ 20°C | Very High | BETAGARD 4050 is moderately corrosive to aluminum, iron and copper, including their alloys. Storage and feeding equipment should be made of plastic or FRP. To maintain polymer activity, storage temperature should not be higher than 38°C. Spills of BETAGARD 4050 can be easily rinsed off with plenty of water. | Available in plastic container sizes with a net weight of 30 kg, 200 kg or 1000 kg. |
Dosage & Application Instructions:
Clarification: 1 to 30 ppm Floatation: Up to 20 ppm Sludge Dewatering: 5 to 40 kg per ton of dry solids.
The actual dosage should be determined in laboratory tube tests. For best results, BETAGARD 4050 should be diluted with clean water and metered continuously into the system with a corrosion resistant positive displacement pump.
BETAGARD 4050 Series
Raw Water Clarifier Floculant
BETAGARD 4050 Series is a low molecular weight concentrated liquid. It is a cationic polydiall dimethyl ammonium chloride, or POLYDADMAC. It works well as a primary coagulant or as a coagulant aid in water or wastewater clarification. This product is chlorine resistant and works over a wide pH range. It can replace inorganic primary coagulants such as alum and ferric salts, or be used together with them. The maximum recommended concentration for BETAGARD 4050 in drinking water treatment is 20 ppm. BETAGARD 4050 is also recommended for other liquid-solids separation processes, such as:
- Dewatering of many industrial and municipal sludges
- Removal of suspended solids from wastewater
- Gravity settling
- Filtration
- Centrifugation
- Air floatation
- Separation of oil and water
- Color Removal
Technical Specifications
| Physical Form | Specific gravity | Ionic Charge | Handling Precautions | Packaging |
|---|---|---|---|---|
| Clear to yellowish colored liquid. | 1.00 - 1.25 @ 20°C | Very High | BETAGARD 4050 is moderately corrosive to aluminum, iron and copper, including their alloys. Storage and feeding equipment should be made of plastic or FRP. To maintain polymer activity, storage temperature should not be higher than 38°C. Spills of BETAGARD 4050 can be easily rinsed off with plenty of water. | Available in plastic container sizes with a net weight of 200 Liters/drum. |
Dosage & Usage Instructions:
Clarification: 1 to 30 ppm Floatation: Up to 20 ppm Sludge Dewatering: 5 to 40 kg per ton of dry solids.
The actual dosage should be determined in laboratory tube tests. For best results, BETAGARD 4050 should be diluted with clean water and metered continuously into the system with a corrosion resistant positive displacement pump.
FAQ
Who supplies coagulants and flocculants for wastewater treatment in Indonesia?
PT Beta Pramesti Asia makes PAC and ACH in its own plant (40,000 tonnes of PAC 12 and 12,000 tonnes of ACH per year). We supply Betagard coagulants in Indonesia for water clarification, wastewater treatment, DAF, oil-water separation and sludge conditioning. If you need stronger floc formation, the coagulant program can be paired with flocculants.
What is the difference between PAC, ACH, and organic coagulants?
PAC on this page includes polyaluminum chloride products such as BETAGARD 4008, 4010, 4012, 4017, 4031 and 4033. ACH includes aluminum chlorohydrate products such as BETAGARD 4040, 4041, 4044 and 4045. Organic coagulants such as BETAGARD 4050 are based on POLYDADMAC. They are used as a primary coagulant or coagulant aid for clarification, DAF, filtration, centrifugation and dewatering.
Can coagulant dosage be selected directly from the product table?
No. The product tables help identify physical form, pH, active content and packaging. However, the actual dosage should be determined through a tube test or jar test in the laboratory and confirmed through a plant trial. Prepare pH, alkalinity, turbidity, TSS, color, oil and grease, flow rate and sludge characteristics before a dosage recommendation is made.
When should a plant contact Beta for a coagulation program review?
Contact Beta when clarification, DAF, filtration or sedimentation is unstable. Also contact us when turbidity, TSS, colour or oil remains high, when flocs break, when chemical use rises, or when sludge is difficult to separate. Send the system data through Beta’s contact page so we can review the product options and the field-trial requirements.
Jar-Test Protocol for Coagulant Selection
A comparable jar test uses an actual sample, recorded initial pH, a fixed injection sequence and the same mixing and settling times for every dose. The objective is not simply the lowest dose. It is the combination that produces stable treated water, separable floc and a sludge volume the downstream process can manage.
| Test step | Conditions to record | Decision criterion |
|---|---|---|
| Sample characterisation | pH, alkalinity, turbidity, TSS, colour, oil/grease and temperature | Establish whether PAC, ACH or an organic coagulant should be compared. |
| Rapid coagulation | Dose in each beaker, chemical order and mixing time | Reject doses that create fragile floc, move pH outside the process range or need impractical aid levels. |
| Flocculation and separation | Slow-mix time, settling or flotation time and supernatant clarity | Compare the outcome with the downstream clarifier, DAF, filtration or dewatering step. |
| Residual verification | Final pH, turbidity/TSS, colour and sludge character | Select candidates that meet the facility’s effluent target and its operational and sludge-management limits. |
| Field trial | Flow, injection point, actual dose and before/after trend | Confirm performance at normal and peak loading before changing the routine programme. |
Betagard coagulants can be paired with flocculants and a chemical dosing pump. Send the jar-test results, flow data and effluent target through Beta’s contact page so we can check the recommendation against the actual process train.
Plant-Trial Decision Sheet for Coagulants
A jar-test candidate is not a routine programme until a plant trial proves water quality, unit operation, sludge impact and chemical use together. Establish a baseline before changing the programme. Use an agreed dose window and record feed conditions so results remain comparable across shifts.
| Trial evidence | Baseline to record | Requirement for acceptance |
|---|---|---|
| Influent and effluent quality | Flow, pH, turbidity/TSS, colour, oil/grease and sample time | The target is met on comparable samples, including the agreed loading conditions. |
| Chemical control | Product, batch, solution concentration, pump setting/calibration and injection point | Actual dose can be calculated and repeated; it does not rely on the pump-dial position alone. |
| Separation performance | Floc-formation time, settling/flotation, carryover and filter condition where relevant | Floc survives to the separation unit without creating a new downstream upset. |
| Sludge impact | Volume, withdrawal frequency, dry solids where measured and dewatering response | Better water quality does not overload the sludge-handling route. |
| Operating stability | Shift results, alarms, upstream changes, rain or production batch | The dose window has response limits and an agreed fallback setting when feed quality changes. |
| Measured cost | kg or L/day at the same flow and load | Compare cost per water volume or pollutant mass treated, not package price alone. |
Record the final decision as accepted, repeat needed, or rejected, with the reason. Include the corresponding flocculant data when asking for review, so the interaction between coagulation and floc formation is not assessed in isolation.
Technical reference: the U.S. EPA explains the roles of coagulation, flocculation, and jar testing in water treatment. Accessed 27 July 2026; wastewater-coagulant selection must still use the facility’s actual sample and process train.