WhatsApp

Ancillaries

What Is an Industrial Clarifier

Updated

An industrial clarifier settles TSS, turbidity, and floc for WTP or wastewater. What it does, the types, and the data that sets its size.

What Is an Industrial Clarifier

Discuss the application.

Send the application, operating conditions and the result you expect. Our team will discuss the options with you.

Ask about this product

or use the contact page

An industrial clarifier is a gravity-settling unit. It separates TSS, turbidity and conditioned floc from raw water, process water or wastewater. PT Beta Pramesti Asia, through beta.co.id, supplies Betaqua clarifiers in Indonesia. We verify flow, TSS, jar testing, settling, blowdown and sludge-route capacity before the unit is selected.

Technically reviewed: 4 August 2026.

Purify your water with our clarifier

Our clarifiers are built for water clarification. The Circular Clarifier has a capacity of 50 m³/h. The Rectangular Clarifier has a capacity of up to 80 m³/h. Both reduce Total Suspended Solids (TSS) or turbidity through gravity settling. They are used for drinking water treatment and for industrial wastewater management. Betaqua clarifiers are reliable and keep water quality within environmental standards and within the needs of our customers.

Advantages

BetaQua clarifiers combine technical design with reliable construction. Each clarifier model has features that improve performance and make operation easier. Our engineering team selects the materials and components. Therefore every clarifier system runs at maximum efficiency with minimal downtime.

Contact our team for a consultation on the clarifier that suits your flow, solids load and sludge route through Beta’s contact page.

Clarifier tank, settling tank, and clarifier basin: what a clarifier does in a WTP or WWTP

A clarifier separates suspended solids (TSS), turbidity and the floc formed by coagulation-flocculation before the water moves to the next stage. It then thickens the sludge for the sludge route. A clarifier is also called a clarifier tank, settling tank or clarifier basin.

In a WTP, the clarifier sits after coagulation-flocculation and before filtration or ultrafiltration. Therefore the solids load on filters and membranes is lower. In a WWTP, it works as primary treatment ahead of the biological stage. It also works as a secondary clarifier after aeration to separate biomass from the treated water.

The two models we supply differ in shape and settling mechanism. The comparison of lamella and circular clarifiers covers that choice. The more compact inclined-plate variant is the stainless steel plate settler.

Betaqua Clarifier Specifications

Both models below can be customised to your needs.

Circular Clarifier

The BetaQua Circular Clarifier gives high efficiency at a capacity of 50 m³/h. It is used to reduce Total Suspended Solids (TSS) or turbidity by gravity settling.

Applications

  • Effluent Treatment Plant Primary Treatment
  • Demin Water Pre-treatment
  • Drinking/Potable Water Clarification
  • Wastewater Treatment Secondary Treatment
  • Mining Heavy Metal Removal

Standard Features

  • Carbon Steel Tank with Epoxy Coating
  • Sludge Scraper
  • Ladder
  • Nozzles and Weir
  • Manual Isolation Valve for Drain/Blowdown

Optional Features

  • Fiber/Rubber Lining for Internal Carbon Steel Tank
  • SS304 Tank
  • Pneumatic Isolation Valve for Drain/Blowdown

Rectangular Clarifier

The Betaqua Rectangular Clarifier is a lamella clarifier with a capacity of 80 m³/h. It maximises TSS or turbidity reduction.

Applications

  • Power Plant Boiler Feed Water Treatment
  • Demin Water Pre-treatment
  • Drinking/Potable Water Clarification
  • Wastewater Primary Treatment

Standard Features

  • Carbon Steel Tank with Epoxy Coating
  • Sludge Scraper
  • Ladder
  • Nozzles and Weir
  • Manual Isolation Valve for Drain/Blowdown

Optional Features

  • Fiber/Rubber Lining for Internal Carbon Steel Tank
  • SS304 Tank
  • FRP Tube Settler/SS304 Lamella Plate Settler
  • Pneumatic Isolation Valve for Drain/Blowdown

Clarifier Selection Data and Solids Loading

We select a clarifier from the actual hydraulic and solids loading, not from tank diameter or average flow alone. Calculate the solids load as TSS (mg/L) × flow (m³/day) ÷ 1,000 = kg TSS/day. Then test whether the solids form settleable floc in the real water. The result shows whether clarification is enough, whether it needs coagulant and flocculant, or whether DAF should be evaluated for oil, grease or poorly settling floc.

Design or operating dataWhy it mattersDecision it supports
Average and peak flowEstablishes actual hydraulic loading and available retention timeUnit size, flow splitting and equalisation need.
TSS, turbidity, colour and oil/greaseSeparates readily settling solids from loading that needs flotation or pretreatmentClarifier suitability versus DAF or filtration.
Jar-test and settling resultsShows floc formation and supernatant clarity at a defined dose and pHCoagulation-flocculation programme and injection-point selection.
Sludge characterVolume, thickening rate and dry-solids percentageHopper capacity, sludge withdrawal schedule and sludge treatment.
Treated-water targetSubsequent use, discharge limit or membrane pretreatmentNeed for final filtration, ultrafiltration or another polishing step.

For a Betaqua clarifier evaluation, send this data with a flow diagram and the history of operating upsets through Beta’s contact page. The technical team can tie unit selection to chemistry testing and the sludge route. Therefore capacity is not assessed from one flow figure alone.

Initial Gate: Clarifier, DAF, or Filtration?

A clarifier is appropriate when solids or conditioned floc settle consistently and the sludge route can receive the separated mass. Test the actual sample before choosing the mechanism. High TSS does not mean that every particle will settle readily.

Evidence from the sample or existing unitFirst route to testReason and next verification
Floc settles, supernatant remains stable, and oil/grease is not dominantGravity clarifierMeasure peak flow, settling rate, sludge volume and carryover.
Fine floc settles poorly or oil/grease must separate with the solidsDAFTest flotation, recycle/air requirement, skimming and clarified-water quality.
Residual solids are low but the polishing target is tighterFiltration or ultrafiltration after primary separationCheck particle size, fouling, backwash, recovery and product-water use.
No stable floc forms at the initial pH and doseOptimise coagulants and flocculants before selecting the unitCompare injection order, mixing, pH, dose and sludge volume through jar testing.
TDS, rather than TSS, limits water useDissolved-ion treatment, not a clarifierComplete ion analysis and assess RO, demineralisation or ion exchange against the target.

As a mass-balance check, a stream of 800 m³/day at 500 mg/L TSS carries 400 kg solids/day. If testing shows 90% capture, the sludge route receives about 360 kg dry solids/day. About 40 kg/day stays in the treated water. This does not give the wet-sludge volume. Measure the dry-solids percentage or the settled volume. Then the hopper, blowdown frequency, sludge tank and dewatering stage are not undersized.

Sometimes the unit also needs chemical-injection hardware and water-treatment components. Then align the package with Watermart dosing pumps for water treatment. Set materials, flow range, pressure and standby duty from the test results and the process diagram. Do not set them from the pipe connection alone.

Industrial clarifier FAQ

Can a clarifier solve every high-TSS problem?

No. A clarifier works well for solids or floc that settle. However, it is weaker for oil, grease, light floc, or very fine particles without conditioning. Settling and jar tests decide whether you need coagulant-flocculant, DAF, filtration, or another step.

What commissioning evidence should be kept for a clarifier?

Keep the actual flow, influent and effluent TSS, turbidity, sludge blanket, blowdown frequency, sludge volume, and chemical dose where used. Also keep photos or notes on carryover. This separates hydraulic, chemistry, and sludge-removal problems.

When should a clarifier be combined with filtration or UF?

Combination treatment is needed when clarified water still carries fine particles, or when the next use has a tighter target. Examples are RO pretreatment, reuse, or process water. Select polishing from particle size, SDI/turbidity, fouling risk, and backwash cost.